CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by TAYLOR, H. J. C.
Right arrow Search for Related Content
PubMed
Right arrow Articles by TAYLOR, H. J. C.

Canadian Journal of Anesthesia, Vol 30, 277-285, Copyright © 1983 by Canadian Anesthesiologists' Society

Clinical Experience with Continuous Epidural Infusion of Bupivacaine at 6 ml per Hour in Obstetrics

HILARY J. C. TAYLOR MB BS FFARCS FRCP(C)1

1 Department of Anaesthesia, Scarborough Centenary Hospital, 2867 Ellesmere Road, West Hill, Ontario M1E 4B9

where correspondence should be addressed to Dr. Taylor.

Maintenance of continuous epidural analgesia for obstetrics by slow infusion is a feasible alternative to maintenance by intermittent injection. The method described by Davies and Fettes using 0.25 per cent bupivacaine through a 6 ml/hr capillary flow device (Intraflo®), with the fast-flush cut-off, is simple and convenient. However, failure of the fast-flush valve, resulting in a high flow rate, as been reported. It is therefore imperative that, prior to connecting the pressurized system to the epidural catheter, correct function of the device be verified by observing the flow rate in the microdrip chamber. We have used this method for the past year and found the equipment reliable, but in order to achieve more satisfactory analgesia the concentration of the infusion was increased initially to 0.375 per cent, and then reduced to 0.30 per cent.

The records of the first 187 patients were reviewed retrospectively. Group I(n = 99) received an infusion of 0.25 per cent bupivacaine, Group II (n = 49) received 0.30 per cent and Group II (n = 39) received 0.375 per cent. Significantly more patients in Group I (30 per cent) required supplementary top-ups (in addition to the infusion) for the first stage of labour than in either Group II (10 per cent), or Group III (13 per cent). Top-ups for delivery were given to 55 per cent of patients in Group I, 4 per cent in Group II and 48 per cent in Group III. The incidence of motor block was significantly higher in roup III (21 per cent) than in either Group I (1 per cent) or Group II (2 per cent). For continuous epidural infusion at 6 ml/hr, 0.30per cent bupivacaine combines optimum analgesia with minimal side-effects.

Key Words: ANAESTHESIA: obstetric • ANAESTHETIC TECHNIQUE: continuous epidural, epidural infusion • ANAESTHETICS, LOCAL: bupivacaine.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the Canadian Anesthesiologists' Society.