CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ghignone, M.
Right arrow Articles by Kozody, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ghignone, M.
Right arrow Articles by Kozody, R.

Canadian Journal of Anesthesia, Vol 34, 46-50, Copyright © 1987 by Canadian Anesthesiologists' Society


ARTICLES

Haemodynamic effects of clonidine injected epidurally in halothane-anaesthetized dogs

M Ghignone, O Calvillo, L Quintin, S Caple and R Kozody

The haemodynamic effects of clonidine administered in the epidural space were studied in 16 halothane-anaesthetized dogs. The animals were randomly assigned to two groups: Group I received three doses of 3 ml of normal saline, Group II received three doses of 3 micrograms X kg-1 of clonidine, through an epidural catheter, whose tip was located between L2-T11. Control haemodynamic measurements were taken one hour after completion of the surgical preparation (period P1); they were repeated every 45 minutes after each incremental dose (periods P2, P3, P4) and 105 minutes after a total cumulative dose of 9 micrograms X kg-1 of clonidine or 9 ml of saline were given (period P5). No significant changes over time were observed in Group I. In Group II clonidine produced statistically significant reductions of systemic blood pressure (BP), mean left ventricular pressure (LV), heart rate (HR), cardiac output (CO) and peak LV dP/dt only after a total clonidine dose of 9 micrograms X kg-1 and these changes were sustained. BP fell 15 per cent, CO 21 per cent, HR 25 per cent, LV 20 per cent and peak LV dP/dt 30 per cent when P5 measurements were compared to control values within Group II (p less than 0.05). These haemodynamic effects of clonidine are likely due to minimal systemic absorption and/or cephalad spread of the drug towards its site of action in the brain stem. The reductions of HR, CO, BP, and isovolemic indices of contractility are likely explained by a reduction of sympathetic outflow at the spinal cord and medulla oblongata levels as well as increased parasympathetic tone.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Br J AnaesthHome page
J. F. Olivier, N. Le, J. L. Choiniere, I. Prieto, F. Basile, and T. Hemmerling
Comparison of three different epidural solutions in off-pump cardiac surgery: pilot study
Br. J. Anaesth., November 1, 2005; 95(5): 685 - 691.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
Y. Ikeda, K. Nishikawa, K. Ohashi, T. Mori, and A. Asada
Epidural Clonidine Suppresses the Baroreceptor-Sympathetic Response Depending on Isoflurane Concentrations in Cats
Anesth. Analg., September 1, 2003; 97(3): 748 - 754.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
D. A. H. de Beer and M. L. Thomas
Caudal additives in children--solutions or problems?
Br. J. Anaesth., April 1, 2003; 90(4): 487 - 498.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the Canadian Anesthesiologists' Society.