CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gaudy, J. H.
Right arrow Articles by Boitier, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gaudy, J. H.
Right arrow Articles by Boitier, J. F.

Canadian Journal of Anesthesia, Vol 34, 122-129, Copyright © 1987 by Canadian Anesthesiologists' Society


ARTICLES

The effects of cremophor EL in the anaesthetized dog

JH Gaudy, JF Sicard, F Lhoste and JF Boitier

The effects of cremophor EL were studied in 13 anaesthetized, paralyzed and ventilated dogs. Twenty per cent cremophor EL in a dose of 4.3 +/- 0.92 ml was infused at a rate of 30 ml X hr-1. In seven dogs, thoracopulmonary compliance, heart rate, systemic arterial pressure (SAP), pulmonary pressures (PAP, PCWP, RAP), cardiac output (CO) and platelet and white cell counts, were measured before the injection of cremophor EL, at the end of infusion and 5, 10, 30 and 150 minutes after the end of infusion. In six dogs, SAP, CO, and blood volume were measured before the injection of cremophor EL, at the end of infusion and 10, 30, 90 and 150 minutes after the end of infusion. Plasma histamine and catecholamines were assayed before the injection of cremophor EL and 2, 5, 10, 30, 90 and 150 minutes after starting the infusion. Cremophor EL induced a marked, sustained and significant decrease in SAP at the end of infusion and at 5, 10 and 30 minutes after the completion of the infusion (-68, -71, -70 and -43 per cent respectively), in PCWP, RAP and CO (-78 per cent at the end of infusion, -32 per cent 150 minutes after the end of infusion). Heart rate and systemic vascular resistance did not vary significantly. Pulmonary vascular resistance increased at the end of infusion, five and ten minutes after the end of infusion (+734, +548 and +439 per cent respectively). Plasma volume decreased 10 and 30 minutes after the end of infusion (-28 and -30.5 per cent respectively).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
HypertensionHome page
M. Ryuzaki, L. K. Stahl, T. Lyson, R. G. Victor, and V. S. Bishop
Sympathoexcitatory Response to Cyclosporin A and Baroreflex Resetting
Hypertension, February 1, 1997; 29(2): 576 - 582.