| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Canadian Journal of Anesthesia, Vol 34, 304-306, Copyright © 1987 by Canadian Anesthesiologists' Society
ARTICLES |
RJ Adderley and GC Mullins
The reliability of "leak" as a criterion for elective extubation of children with croup treated with nasotracheal intubation was studied during the three month "croup epidemic" in Ontario of September 1, 1983 to November 30, 1983. Twenty-eight patients experienced 36 extubations; 31 planned and five accidental. Three of 23 (13 per cent) planned extubations with "leak" required reintubation whereas three of eight (38 per cent) children electively extubated after seven days of intubation without "leak" required reintubation. "Leak" is a helpful but not absolute prognostic indicator of a successful extubation.
This article has been cited by other articles:
![]() |
M. Meade, G. Guyatt, D. Cook, L. Griffith, T. Sinuff, C. Kergl, J. Mancebo, A. Esteban, and S. Epstein Predicting Success in Weaning From Mechanical Ventilation Chest, December 1, 2001; 120(6_suppl): 400S - 424S. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Engoren Evaluation of the Cuff-Leak Test in a Cardiac Surgery Population Chest, October 1, 1999; 116(4): 1029 - 1031. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |