CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rolbin, S. H.
Right arrow Articles by Ogilvie, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rolbin, S. H.
Right arrow Articles by Ogilvie, G.

Canadian Journal of Anesthesia, Vol 34, 459-461, Copyright © 1987 by Canadian Anesthesiologists' Society


ARTICLES

A comparison of two types of epidural catheters

SH Rolbin, E Hew and G Ogilvie
Department of Anaesthesia, Mount Sinai Hospital, University of Toronto, Ontario.

The purpose of this study was to compare two epidural catheters--the Portex epidural catheter and Vas-Cath catheter. One hundred and fifty patients in labour who received epidural anaesthesia were selected and either one or the other catheter was used, based on random assignment. Ease of insertion, maintenance and removal of the catheter were assessed, as was the incidence of blood return and paraesthesiae during epidural catheter insertion. There were no significant differences between the catheters as far as insertion, maintenance and removal were concerned. However, the incidence of paresthesiae was 44 per cent with the Portex and 24 per cent with Vas-Cath catheters (p less than 0.008). The incidence of blood vessel trauma was 12 per cent with the Portex and 6.7 per cent with the Vas-Cath catheter (p = NS). Choice of epidural catheter is a factor to be considered in minimizing the incidence of blood vessel trauma or paresthesiae.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
I. M. Browne, D. J. Birnbach, D. J. Stein, D. A. O'Gorman, and M. Kuroda
A Comparison of Espocan(R) and Tuohy Needles for the Combined Spinal-Epidural Technique for Labor Analgesia
Anesth. Analg., August 1, 2005; 101(2): 535 - 540.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
I. Rice, M. Y. K. Wee, and K. Thomson
Obstetric epidurals and chronic adhesive arachnoiditis
Br. J. Anaesth., January 1, 2004; 92(1): 109 - 120.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
N. Campbell and O. P. Rosaeg
Anesthetic management of a parturient with Ehlers Danlos syndrome type IV: [L'anesthesie d'une parturiente atteinte du syndrome d'Ehlers Danlos de type IV]
Can J Anesth, May 1, 2002; 49(5): 493 - 496.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. G. Richardson and R. N. Wissler
The Effects of Needle Bevel Orientation During Epidural Catheter Insertion in Laboring Parturients
Anesth. Analg., February 1, 1999; 88(2): 352 - 352.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the Canadian Anesthesiologists' Society.