CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by D'Athis, F.
Right arrow Articles by Eledjam, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by D'Athis, F.
Right arrow Articles by Eledjam, J. J.

Canadian Journal of Anesthesia, Vol 35, 116-122, Copyright © 1988 by Canadian Anesthesiologists' Society


ARTICLES

Epidural analgesia with a bupivacaine-fentanyl mixture in obstetrics: comparison of repeated injections and continuous infusion

F D'Athis, M Macheboeuf, H Thomas, C Robert, G Desch, M Galtier, P Mares and JJ Eledjam
Departement d'Anesthesie Reanimation, CHR, Nimes, France.

We compared the efficacy and side-effects of continuous infusion versus repeated injections of epidural bupivacaine-fentanyl during labour. Forty-four parturients were randomly distributed into two groups balanced for population size, morphology and parity. Analgesia was begun at the same stage of labour with a mixture of 20 ml 0.25 per cent plain bupivacaine and 2 ml (100 micrograms) fentanyl. In Group I the initial dose ranged from 8-12 ml as a function of height; an injection of the same dose was repeated immediately upon recurrence of pain. In Group II, after an initial dose of 5-7 ml, a continuous infusion of 3 ml.h-1 was begun, and continued until full dilatation. Analgesia was rated using a pain scale; effects on maternal blood pressure, respiratory rate and neonatal status were noted. Bupivacaine and fentanyl assays were carried out on maternal venous blood in 30 parturients during the course of labour. There was a longer latency to onset of analgesia in Group II (approximately five minutes), followed by a more constant degree of analgesia. This better analgesia cannot be accounted for by a difference in dosage; doses were significantly lower in Group II, despite the fact that labour was of the same duration. The course of labour, and maternal and neonatal status were comparable in the two groups. Assays showed no difference in bupivacaine blood concentrations between the two groups nor signs of drug accumulation. The constant infusion technique is advantageous since it provides a more regular degree of analgesia with lower doses than those required for patients having repeated injections.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the Canadian Anesthesiologists' Society.