CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McNulty, S. E.
Right arrow Articles by McQueen, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McNulty, S. E.
Right arrow Articles by McQueen, J.

Canadian Journal of Anesthesia, Vol 35, 309-311, Copyright © 1988 by Canadian Anesthesiologists' Society


ARTICLES

Temporary A-V sequential pacing using transluminal pacing electrodes

SE McNulty and J McQueen
Department of Anesthesiology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania 19107.

A case is presented which describes the initiation of atrial-ventricular (A-V) sequential pacing using atrial epicardial wires and an in-situ transluminal ventricular pacing probe. A 68-year-old female with a permanent A-V sequential pacemaker was scheduled for elective aortocoronary bypass. Following sternotomy, pacing function was converted to ventricular pacing (VVI) with the use of electrocautery. A Chandler V-pacing probe was introduced through a Paceport (American Edwards) pulmonary artery catheter and with a paced increase in ventricular rate, the cardiac output increased from 2.8 to 3.2 L.min-1. At the conclusion of cardiopulmonary bypass the patient was in sinus rhythm at a rate of 67.min-1 and was paced to a faster rate using bipolar atrial epicardial wires. The patient subsequently developed intermittent heart block so temporary A-V sequential pacing was established using atrial epicardial wires and the in situ ventricular pacing probe. Pacing was achieved at routine generator output settings of seven milliamps (mA) for both atrium and ventricle and at an A-V interval of 0.120 sec. This resulted in an immediate increase in cardiac output from 3.3 to 4.1 L.min-1. The compatibility of these two pacing systems offers an increased margin of safety in cardiac surgery patients requiring atrial pacing, who are at risk for developing postoperative heart block.