CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robbins, G. R.
Right arrow Articles by Patel, Y. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Robbins, G. R.
Right arrow Articles by Patel, Y. C.

Canadian Journal of Anesthesia, Vol 37, 52-57, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

Pharmacokinetics of alfentanil and clinical responses during cardiac surgery

GR Robbins, JE Wynands, DG Whalley, F Donati, JG Ramsay, CB Srikant and YC Patel
Department of Anaesthesia, Royal Victoria Hospital, Montreal, Quebec.

This study assessed the pharmacokinetic and pharmacodynamic behaviour of alfentanil during and after coronary artery bypass grafting (CABG). Twenty-eight patients with good ventricular function having CABG were divided into three groups and premedicated with morphine 0.1 mg.kg-1 IM, scopolamine 0.005 mg.kg-1 IM and diazepam 0.1 mg.kg-1 PO. Group I patients received an infusion of 250 micrograms.kg-1 of alfentanil over one hour coincidental with a second infusion at 2.5 micrograms.kg-1.min-1 which was continued to the end of surgery. Patients in group II received 300 micrograms.kg-1 and 3.0 micrograms.kg-1.min-1 and patients in group III 350 micrograms.kg-1 and 3.5 micrograms.kg-1.min-1. The tracheas of all patients were intubated after receiving alfentanil 96 micrograms.kg-1 and pancuronium 0.15 micrograms.kg-1. Haemodynamic responses to intubation and surgical stimuli (greater than or equal to 20 per cent increase in heart rate and/or systolic blood pressure from control) were treated with isoflurane, one to two per cent inspired, until abolished. Blood samples were taken during and after surgery for plasma alfentanil concentrations which were determined by radioimmunoassay. After surgery the times to awakening and extubation, and alfentanil elimination half-life (t1/2B = 0.693/-k) were determined for each patient. Haemodynamic responses occurred in 20 patients. There were no significant differences in any variable among the groups. The times to awakening and extubation for all patients were 3.2 +/- 0.6 and 8.8 +/- 1.2 hr (mean +/- SEM) respectively. The elimination half-life for all patients was 5.1 +/- 1.0 hr (mean +/- SEM).(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Canadian Anesthesiologists' Society.