CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Herrick, I. A.
Right arrow Articles by Froese, A. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herrick, I. A.
Right arrow Articles by Froese, A. B.

Canadian Journal of Anesthesia, Vol 37, 69-76, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

A clinical comparison of indices of pulmonary gas exchange with changes in the inspired oxygen concentration

IA Herrick, LK Champion and AB Froese
Department of Anaesthesia, Queen's University, Kingston, Ontario, Canada.

Several indices have been introduced as convenient alternatives to calculation of the physiological shunt fraction (Qs/QT) for the assessment of pulmonary gas exchange. These include: the arterial-alveolar oxygen tension ratio (a/APO2), the arterial oxygen tension-inspired oxygen concentration ratio (PaO2/FIO2), the respiratory index (RI), [A-a)DO2/PaO2) and the alveolar-arterial oxygen tension difference [A-a)Do2). These indices are in use clinically despite the fact that they may not accurately predict gas exchange in situations where FIO2, Qs/QT or arterial-venous oxygen content is changing. The clinical stability of each of these indices, relative to the behaviour of the physiological shunt, was therefore investigated prospectively in ten mechanically ventilated postoperative adults as FIO2 was varied from 0.30 to 1.00. None of the indices studied reliably reflected the behaviour of the physiological shunt. As FIO2 was increased incrementally from 0.30 to 1.00, 42 to 55 per cent of the measured changes in these indices were opposite in direction to the corresponding changes in the physiological shunt. The maximum magnitudes of the opposite changes were substantial; 24 and 22 per cent for the a/APO2 and PaO2/FIO2 ratio respectively, 67 per cent for the RI and 101 per cent for the (A-a)DO2. We conclude that the use of any of these indices for clinical assessment of a patient's gas exchange defect when FIO2 is varying can be substantially misleading.