CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baraka, A.
Right arrow Articles by Dalleh, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baraka, A.
Right arrow Articles by Dalleh, R.

Canadian Journal of Anesthesia, Vol 37, 641-644, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

Maternal awareness and neonatal outcome after ketamine induction of anaesthesia for Caesarean section

A Baraka, F Louis and R Dalleh
Department of Anesthesiology, American University of Beirut, Lebanon.

Ketamine was used as the sole anaesthetic during the induction-to-delivery interval in 20 full-term patients undergoing elective Caesarean section. The intravenous administration of ketamine 1.5 mg.kg-1 was followed by succinylcholine 1.5 mg.kg-1 and tracheal intubation. The mother's lungs were then ventilated using 100 per cent oxygen until the baby was delivered. Intraoperative maternal awareness was assessed by the isolated forearm technique. The Apgar scores of the newborn at one and five minutes, as well as their umbilical vein blood gases were also evaluated and correlated with the induction-to-delivery (I-D) and the uterine incision-to-delivery (U-D) intervals. In 13 patients (Group A) the I-D interval was less than 10 min and U-D interval less than 90 sec, while in seven (Group B) the I-D interval was greater than or equal to 10 min and the U-D interval greater than or equal to 90 sec. The isolated arm test was negative in all patients having an I-D interval less than 10 min, and was positive in three patients when the I-D interval exceeded ten minutes. The newborns of group A showed higher Apgar scores at one minute, as well as higher umbilical vein PO2 than was achieved in Group B. It was concluded that the technique used was not associated with maternal awareness or neonatal depression, provided that the I-D interval was less than 10 min and the U-D interval was less than 90 sec.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
D. Strumper, W. Gogarten, M. E. Durieux, K. Hartleb, H. Van Aken, and M. A. E. Marcus
The Effects of S(+)-Ketamine and Racemic Ketamine on Uterine Blood Flow in Chronically Instrumented Pregnant Sheep
Anesth. Analg., February 1, 2004; 98(2): 497 - 502.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Canadian Anesthesiologists' Society.