CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dimich, I.
Right arrow Articles by Jhaveri, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dimich, I.
Right arrow Articles by Jhaveri, M.

Canadian Journal of Anesthesia, Vol 38, 985-988, Copyright © 1991 by Canadian Anesthesiologists' Society


ARTICLES

Evaluation of oxygen saturation monitoring by pulse oximetry in neonates in the delivery system

I Dimich, PP Singh, A Adell, M Hendler, N Sonnenklar and M Jhaveri
Department of Anesthesiology, Mount Sinai Medical School, New York, New York.

The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.


This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
J A Dawson, P G Davis, C P F O'Donnell, C O F Kamlin, and C J Morley
Pulse oximetry for monitoring infants in the delivery room: a review
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2007; 92(1): F4 - F7.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
L M O'Brien, V A Stebbens, C F Poets, E G Heycock, and D P Southall
Oxygen saturation during the first 24 hours of life
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2000; 83(1): 35F - 38.
[Abstract] [Full Text]


Home page
CLIN PEDIATRHome page
V. K. Reddy, I. R. Holzman, and J. F. Wedgwood
Pulse Oximetry Saturations in the First 6 Hours of Life in Normal Term Infants
Clinical Pediatrics, March 1, 1999; 38(2): 87 - 92.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the Canadian Anesthesiologists' Society.