CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tweed, W. A.
Right arrow Articles by Lee, T. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tweed, W. A.
Right arrow Articles by Lee, T. L.

Canadian Journal of Anesthesia, Vol 38, 989-995, Copyright © 1991 by Canadian Anesthesiologists' Society


ARTICLES

Large tidal volume ventilation improves pulmonary gas exchange during lower abdominal surgery in Trendelenburg's position

WA Tweed, WT Phua, KY Chong, E Lim and TL Lee
Department of Anaesthesia, National University Hospital, National University of Singapore.

Impaired pulmonary gas exchange is a common complication of general anaesthesia. Periodic hyperinflation of the lungs and large tidal volume ventilation were the first preventive measures to be widely embraced, but their effectiveness in clinical practice has never been clearly established by controlled clinical studies. To assess their effects in high-risk patients we studied 24 adults having lower abdominal gynaecological surgery in the Trendelenburg (head down) position. Pulmonary oxygen exchange was determined during four steady-states: awake control (AC), after 30 min of conventional tidal volume (CVT, 7.5 ml.kg-1) or high tidal volume (HVT, 12.7 ml.kg-1) ventilation, introduced in random order, and five minutes after manual hyperinflations (HI) of the lungs. The patients' lungs were ventilated with air/O2 by an Ohmeda volume-controlled ventilator via a circle system. The FIO2 was controlled at 0.5, and FETCO2 was controlled by adding dead space during HVT. Arterial blood gas analysis was used to calculate the oxygen tension-based indices of gas exchange. There was significant deterioration of (A-a)DO2 at 30 min in Group A, whose lungs were first ventilated with CVT (81.6 +/- 7.2 to 166.8 +/- 13.7 mmHg, P less than 0.001); but not in Group B, whose lungs were first ventilated with HVT (77.0 +/- 9.9 to 104.4 +/- 16.8 mmHg). When Group A and B data were pooled there was no difference between randomized CVT and HVT, but improvement occurred after HI. In this model of compromised O2 exchange large inflation volumes (HVT and HI) were of considerable clinical benefit, HVT prevented and HI reversed the gas exchange disorder.


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Sekine, Y. Miyata, K. Yamada, H. Yamada, T. Yasukawa, Y. Saitoh, S. Yoshida, and T. Fujisawa
Video-assisted thoracoscopic surgery does not deteriorate postoperative pulmonary gas exchange in spontaneous pneumothorax patients
Eur. J. Cardiothorac. Surg., July 1, 1999; 16(1): 48 - 53.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
M. L. Fisher and S. C. Body
Physiology of One-Lung Ventilation
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 1997; 1(3): 236 - 255.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the Canadian Anesthesiologists' Society.