CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crosby, E. T.
Right arrow Articles by Halpern, S. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Crosby, E. T.
Right arrow Articles by Halpern, S. H.

Canadian Journal of Anesthesia, Vol 39, 313-316, Copyright © 1992 by Canadian Anesthesiologists' Society


ARTICLES

Supplemental maternal oxygen therapy during caesarean section under epidural anaesthesia: a comparison of nasal prongs and facemask

ET Crosby and SH Halpern
Department of Anaesthesia, Ottawa General Hospital, University of Ottawa, Toronto, Canada.

Forty healthy parturients at term, undergoing elective Caesarean section, were divided into two groups to receive supplemental oxygen by either simple facemask (Group FM, 8 L.min-1) or nasal prongs (Group NP, 4 L.min-1) during the procedure. Anaesthesia was provided by epidural block to equivalent dermatomal levels in all patients. Maternal oxygen saturation was measured continuously with pulse oximetry and supplemental oxygen was provided to the mother after administration of the epidural test dose and continued until the end of the procedure. Following delivery of the infant and concurrent with Apgar scoring, the umbilical cord was double-clamped and arterial and venous samples were drawn. The pH, partial pressures of O2 and CO2 and O2 saturations were measured. There was no difference in the clinical condition of the neonates, as assessed by Apgar scores, or in the acid-base and oxygenation status, as assessed by blood gas analyses between the two groups. Mean umbilical vein oxygen saturation, a measure of fetal oxygen delivery, was 46 +/- 18% (95% confidence interval 39% to 54%) for Group NP and 54 +/- 17% (95% confidence interval 46% to 62%) for Group FM, again not different. We conclude that when the clinical condition, acid-base and oxygenation status of neonates, delivered by elective Caesarean section to healthy, low-risk parturients with normal placental function under epidural anaesthesia, are evaluated, it makes no difference whether the mothers received supplemental oxygen by nasal prongs or simple facemask.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
K. S. Khaw, C. C. Wang, W. D. Ngan Kee, C. P. Pang, and M. S. Rogers
Effects of high inspired oxygen fraction during elective Caesarean section under spinal anaesthesia on maternal and fetal oxygenation and lipid peroxidation{dagger}
Br. J. Anaesth., January 1, 2002; 88(1): 18 - 23.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the Canadian Anesthesiologists' Society.