| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Canadian Journal of Anesthesia, Vol 39, 617-632, Copyright © 1992 by Canadian Anesthesiologists' Society
ARTICLES |
K Bhavani-Shankar, H Moseley, AY Kumar and Y Delph
Department of Anaesthesia, Queen Elizabeth Hospital, University of West Indies, Barbados.
In the last decade, capnography has developed from a research instrument into a monitoring device considered to be essential during anaesthesia to ensure patient safety. Hence, a comprehensive understanding of capnography has become mandatory for the anaesthetist in charge of patients in the operating room and in the intensive care unit. This review of capnography includes the methods available to determine carbon dioxide in expired air, and an analysis of the physiology of capnograms, which are followed by a description of the applications of capnography in clinical practice. The theoretical backgrounds of the effect of barometric pressure, water vapour, nitrous oxide and other factors introducing errors in the accuracy of CO2 determination by the infra-red technique, currently the most popular method in use, are detailed. Physiological factors leading to changes in end-tidal carbon dioxide are discussed together with the clinical uses of this measurement to assess pulmonary blood flow indirectly, carbon dioxide production and adequacy of alveolar ventilation. The importance of understanding the shape of the capnogram as well as end-tidal carbon dioxide measurements is emphasized and its use in the early diagnosis of adverse events such as circuit disconnections, oesophageal intubation, defective breathing systems and hypoventilation is highlighted. Finally, the precautions required in the use and interpretation of capnography are presented with the caveat that although no instrument will replace the continuous presence of the attentive physician, end-tidal carbon dioxide monitoring can be effective in the early detection of anaesthesia-related intraoperative accidents.
This article has been cited by other articles:
![]() |
U. Lucangelo, F. Bernabe, S. Vatua, G. Degrassi, A. Villagra, R. Fernandez, P. V. Romero, P. Saura, M. Borelli, and L. Blanch Prognostic Value of Different Dead Space Indices in Mechanically Ventilated Patients With Acute Lung Injury and ARDS Chest, January 1, 2008; 133(1): 62 - 71. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Takla, J. H. Petre, D. J. Doyle, M. Horibe, and B. Gopakumaran The Problem of Artifacts in Patient Monitor Data During Surgery: A Clinical and Methodological Review Anesth. Analg., November 1, 2006; 103(5): 1196 - 1204. [Abstract] [Full Text] [PDF] |
||||
![]() |
M J Donald and B Paterson End tidal carbon dioxide monitoring in prehospital and retrieval medicine: a review. Emerg. Med. J., September 1, 2006; 23(9): 728 - 730. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Kwetny and B. T. Finucane Negative arterial to end-tidal carbon dioxide gradient: an additional sign of malignant hyperthermia during desflurane anesthesia. Anesth. Analg., March 1, 2006; 102(3): 815 - 817. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. S. Kodali Capnogram Shape in Obstructive Lung Disease Anesth. Analg., November 1, 2005; 101(5): 1560 - 1560. [Full Text] [PDF] |
||||
![]() |
D G Tingay, M J Stewart, and C J Morley Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2005; 90(6): F523 - F526. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Yosefy, E Hay, Y Nasri, E Magen, and L Reisin End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting Emerg. Med. J., September 1, 2004; 21(5): 557 - 559. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Griffin, B. E. Terry, R. K. Burton, T. L. Ray, B. P. Keller, A. L. Landrum, J. O. Johnson, and J. D. Tobias Comparison of end-tidal and transcutaneous measures of carbon dioxide during general anaesthesia in severely obese adults Br. J. Anaesth., October 1, 2003; 91(4): 498 - 501. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Tschupp and S. Fanconi A Combined Ear Sensor for Pulse Oximetry and Carbon Dioxide Tension Monitoring: Accuracy in Critically Ill Children Anesth. Analg., January 1, 2003; 96(1): 82 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Broka and S. Boujlel Capnography and Severe COPD Anesth. Analg., January 1, 2002; 94(1): 235 - 235. [Full Text] [PDF] |
||||
![]() |
P. Seguin, J. P. Bleichner, B. Branger, Y. M. Guillou, A. Feuillu, and Y. Malledant La pression tele expiratoire en CO2 n'est pas un parametre pertinent de surveillance d'un traumatisme cranien grave Can J Anesth, April 1, 2001; 48(4): 396 - 400. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Grenier, E. Verchere, A. Mesli, M. Dubreuil, D. Siao, M. Vandendriessche, J. Cales, and P. Maurette Capnography Monitoring During Neurosurgery: Reliability in Relation to Various Intraoperative Positions Anesth. Analg., January 1, 1999; 88(1): 43 - 48. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Rozycki, G. D. Sysyn, M. K. Marshall, R. Malloy, and T. E. Wiswell Mainstream End-tidal Carbon Dioxide Monitoring in the Neonatal Intensive Care Unit Pediatrics, April 1, 1998; 101(4): 648 - 653. [Abstract] [Full Text] [PDF] |
||||