CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spahr-Schopfer, I. A.
Right arrow Articles by Hartley, E. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spahr-Schopfer, I. A.
Right arrow Articles by Hartley, E. J.

Canadian Journal of Anesthesia, Vol 40, 1038-1043, Copyright © 1993 by Canadian Anesthesiologists' Society


ARTICLES

Capnometry and the paediatric laryngeal mask airway

IA Spahr-Schopfer, B Bissonnette and EJ Hartley
Department of Anaesthesia, Hospital for Sick Children, Toronto, Ontario, Canada.

The laryngeal mask airway (LMA), an alternative to tracheal intubation in certain situations, has gained popularity in recent years. Initially designed for use in adults it has now become available in suitable sizes for paediatric anaesthesia. The objectives of this study were to identify the preferred site of sampling the end-tidal carbon dioxide (PETCO2) with the LMA and to determine the accuracy of this recording when compared with arterial CO2 (PaCO2). We studied 30 healthy children, age one to five years and weighing between 10 and 25 kg undergoing minor surgery requiring mask anaesthesia. In each case, after induction of anaesthesia, the LMA was inserted under direct vision to eliminate the possibility of epiglottic airway obstruction. The fresh gas flow was provided by a Jackson Rees modification of an Ayre's T-piece and was determined according to the following formula: 3 x (1000 + (100 x body weight)) LPM. Blood pressure, ECG, O2 saturation, temperature and end-tidal gas concentrations were recorded. The measures of peak PETCO2 were taken at pre-determined distances from the elbow connector down the LMA shaft. During the sampling sequence an arterial blood sample was taken for gas analysis. The PaCO2 was 63.5 +/- 9.3 mmHg (mean +/- SD). At any given sampling site, mean PETCO2 values were less than PaCO2 (P < 0.05). However, in eight patients PETCO2 values measured at the distal site were higher than the PaCO2 (negative P(a-ET)CO2 gradients).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Br J AnaesthHome page
K. Goldmann, C. Roettger, and H. Wulf
Use of the ProSealTM laryngeal mask airway for pressure-controlled ventilation with and without positive end-expiratory pressure in paediatric patients: a randomized, controlled study
Br. J. Anaesth., December 1, 2005; 95(6): 831 - 834.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the Canadian Anesthesiologists' Society.