| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Canadian Journal of Anesthesia, Vol 40, 279-282, Copyright © 1993 by Canadian Anesthesiologists' Society
ARTICLES |
RL Knill
Department of Anaesthesia, University Hospital, University of Western Ontario, London, Canada.
Displacement of the larynx by backward, upward and rightward pressure on the thyroid cartilage or "BURP" may improve visualization of the glottis in some cases of difficult direct laryngoscopy. In a patient with the Treacher-Collins syndrome in whom conventional laryngoscopy had proved impossible and tracheal intubation extremely difficult, this manoeuvre exposed the entire glottis and made tracheal intubation under direct vision easy. In a patient with protruding upper incisors and a prominent premaxilla which precluded a view of the glottis by conventional laryngoscopy, "BURP" again revealed the glottic opening and simplified the placement of an endotracheal tube. This experience suggests that "BURP" be considered as a potential aid in the management of difficult direct laryngoscopy.
This article has been cited by other articles:
![]() |
P. Cortellazzi, L. Minati, C. Falcone, M. Lamperti, and D. Caldiroli Predictive value of the El-Ganzouri multivariate risk index for difficult tracheal intubation: a comparison of Glidescope(R) videolaryngoscopy and conventional Macintosh laryngoscopy Br. J. Anaesth., December 1, 2007; 99(6): 906 - 911. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. W. Cheung, M. G. Irwin, B. C. W. Law, and C. K. Chan A Clinical Comparison of the FlexibladeTM and Macintosh Laryngoscopes for Laryngeal Exposure in Anesthetized Adults Anesth. Analg., February 1, 2006; 102(2): 626 - 630. [Abstract] [Full Text] [PDF] |
||||
![]() |
J E Ollerton, M J A Parr, K Harrison, B Hanrahan, and M Sugrue Potential cervical spine injury and difficult airway management for emergency intubation of trauma adults in the emergency department--a systematic review Emerg. Med. J., January 1, 2006; 23(1): 3 - 11. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. McCaul, D. Harney, M. Ryan, C. Moran, B. P. Kavanagh, and J. F. Boylan Airway Management in the Lateral Position: A Randomized Controlled Trial Anesth. Analg., October 1, 2005; 101(4): 1221 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. H. J. Eberhart, C. Arndt, T. Cierpka, J. Schwanekamp, H. Wulf, and C. Putzke The Reliability and Validity of the Upper Lip Bite Test Compared with the Mallampati Classification to Predict Difficult Laryngoscopy: An External Prospective Evaluation Anesth. Analg., July 1, 2005; 101(1): 284 - 289. [Abstract] [Full Text] [PDF] |
||||
![]() |
A D Paix, J A Williamson, and W B Runciman Crisis management during anaesthesia: difficult intubation Qual. Saf. Health Care, June 1, 2005; 14(3): e5 - e5. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Snider, D. Clarke, and B. T. Finucane The "BURP" maneuver worsens the glottic view when applied in combination with cricoid pressure: [La manoeuvre PAHD, combinee a la compression cricoidienne, degrade la visualisation de la glotte] Can J Anesth, January 1, 2005; 52(1): 100 - 104. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Carley and C. Gwinnutt Stepwise airway management in the trauma patient Trauma, July 1, 2004; 6(3): 177 - 185. [Abstract] [PDF] |
||||
![]() |
S D Carley, C Gwinnutt, J Butler, I Sammy, and P Driscoll Rapid sequence induction in the emergency department: a strategy for failure Emerg. Med. J., March 1, 2002; 19(2): 109 - 113. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Preis and I. Preis Removal of the connector on the laryngeal mask airway provides a useful alternative to the intubating laryngeal mask : [Le retrait du connecteur du masque larynge permet une utilisation equivalente au masque larynge d'intubation] Can J Anesth, June 1, 2001; 48(6): 600 - 603. [Abstract] [Full Text] |
||||
![]() |
T. Heidegger, H. J. Gerig, B. Ulrich, and G. Kreienbuhl Validation of a Simple Algorithm for Tracheal Intubation: Daily Practice Is the Key to Success in Emergencies-- An Analysis of 13,248 Intubations Anesth. Analg., February 1, 2001; 92(2): 517 - 522. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Preis, C. Czerny, I. Preis, and M. Zimpfer Variations in ILMA external diameters: another cause of device failure Can J Anesth, September 1, 2000; 47(9): 886 - 889. [Abstract] [Full Text] [PDF] |
||||