CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Roth, A. G.
Right arrow Articles by Hall, S. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Roth, A. G.
Right arrow Articles by Hall, S. C.

Canadian Journal of Anesthesia, Vol 41, 1069-1073, Copyright © 1994 by Canadian Anesthesiologists' Society


ARTICLES

Comparison of a rigid laryngoscope with the ultrathin fibreoptic laryngoscope for tracheal intubation in infants

AG Roth, M Wheeler, GW Stevenson and SC Hall
Department of Anesthesia, Children's Memorial Hospital, Chicago, Illinois 60614.

The flexible ultrathin fibreoptic laryngoscope allows placement of endotracheal tubes as small as 2.5 mm internal diameter. The purpose of this study was to document the safety and efficacy of intubation using an ultrathin fibreoptic laryngoscope. Proved safety and efficacy would justify the routine use of fibreoptic laryngoscopy in normal infants to maintain skills needed for management of the difficult infant airway. In this prospective study, 40 infants < 24 mo of age scheduled for elective surgery were randomly divided into two equal groups. After inhalation induction of anaesthesia, in 20 infants the trachea was intubated using direct rigid laryngoscopy, and in 20 using the ultrathin fibreoptic laryngoscope (size 1.8 mm OD) Olympus LFP. Time to successful intubation was recorded, as well as blood pressure, heart rate, end-tidal CO2 and oxygen saturation. Airway trauma in the operating room, the post-anaesthesia care unit, and on the first postoperative day was recorded. The intubation times using rigid laryngoscopy were less than those using fibreoptic laryngoscopy (13.6 +/- 0.9 sec (mean +/- SEM) vs 22.8 +/- 1.7 sec; P < 0.01). Oxygen saturation and end-tidal CO2 readings were not different between the two groups. After intubation, blood pressure and heart rate increased equally in both groups, returning to normal within one to two minutes. There was no difference in the airway trauma between groups. We conclude that the ultrathin fibreoptic laryngoscope is a safe and effective method for tracheal intubation in infants and may be used routinely in order to maintain fibreoptic airway skills.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
F. S. Xue, C. W. Li, K. P. Liu, H. T. Sun, G. H. Zhang, Y. C. Xu, and Y. Liu
Circulatory Responses to Fiberoptic Intubation in Anesthetized Children: A Comparison of Oral and Nasal Routes
Anesth. Analg., February 1, 2007; 104(2): 283 - 288.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
T. Asai and K. Shingu
Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions
Br. J. Anaesth., June 1, 2004; 92(6): 870 - 881.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the Canadian Anesthesiologists' Society.