CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Charters, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Charters, P.

Canadian Journal of Anesthesia, Vol 41, 594-602, Copyright © 1994 by Canadian Anesthesiologists' Society


ARTICLES

Analysis of mathematical model for osseous factors in difficult intubation

P Charters
Department of Anaesthesia, Aintree Hospitals NHS Trust, Walton Hospital, Liverpool, UK.

A two-dimensional model of the factors relevant to difficult laryngoscopy was analysed mathematically to determine clinical implications and limitations. The model describes the space into which the "inevitable residual volume" of the tongue (that part remaining anterior to the blade at laryngoscopy) can be displaced to permit a view of the larynx. Four points are used: the tip of the upper incisors; a point on the anterior airway just above the larynx; the mid-point between the mandibular condyles and the internal mid-point of the symphysis. The number, F, was defined by a formula developed from their spacial relationships. Decreasing F values imply an increasing likelihood of difficult laryngoscopy. The analysis investigated the effects of: translation of individual points; plotting individual point positions for specified F-values; translating adjacent pairs of points; treating any three points as a triangle which rotates about each of its apices; and lastly, translating three points independently. During manipulations the model behaved well mathematically. Single point analysis implied that jaw recession and a non-protruding mandible were comparable in effect. Closing the mouth around the laryngoscope blade maximised F-values. Prominence of the maxilla required greater forward displacement than backward movement of the symphysis for equivalent F-value change. One particular triangular rotation suggested an entirely novel mechanism for difficulty (the "hi-slung mandible") where the condyles are positioned more rostral than normal. An otherwise normal jaw with this configuration recedes markedly on opening. Further studies are required to validate the model. Accurate quantification of individual factors in difficult laryngoscopy may then be feasible.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. D. Aiken, N. Delson, T. M. Davidson, and R. H. Hastings
A Two-Dimensional Model of Anatomic Relationships During Laryngoscopy
Anesth. Analg., October 1, 2007; 105(4): 1118 - 1126.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
R. B. George, D. McKeen, and J. A. Law
Laryngoscopic evaluation with the Airway Cam(R) laryngoscopy video system: [Evaluation laryngoscopique avec le systeme de laryngoscopie video Airway Cam(R)].
Can J Anesth, May 1, 2006; 53(5): 512 - 515.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the Canadian Anesthesiologists' Society.