CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schott, U.
Right arrow Articles by Bjorsell-Ostling, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schott, U.
Right arrow Articles by Bjorsell-Ostling, E.

Canadian Journal of Anesthesia, Vol 42, 64-68, Copyright © 1995 by Canadian Anesthesiologists' Society


ARTICLES

Sonoclot coagulation analysis and plasma exchange in a case of meningococcal septicaemia

U Schott and E Bjorsell-Ostling
Department of Anesthesia and Intensive Care, Orebro Medical Center Hospital, Sweden.

On the basis of a patient with fulminant meningococcaemia and severe disseminated intravascular coagulation (DIC) syndrome, the diagnostic potential of a clot impedance test - Sonoclot coagulation analysis - was used to evaluate plasma exchange. A 17-yr-old girl was treated for a fulminant infection with Neisseria meningitidis in our intensive care unit. She developed severe DIC. Whereas platelet administration caused immediate arterial oxygen desaturation necessitating ventilatory support, plasma exchange improved pulmonary and mental function. Three separate exchanges all improved haemostasis. Sonoclot analysis was used together with routine coagulation analyses to evaluate this DIC treatment. Sonoclot signs, such as lack of the shoulder and peak, prolonged shoulder-peak interval and peak time predicted clinical bleeding manifestations (haematuria, haemoptysis, epistaxis) and were improved by platelet transfusion and plasma exchange. Plasma exchange was successful even at a very low platelet count of < 23 x 10(9).L-1. Sonoclot coagulation analyses were normalised several days before routine coagulation analyses. The Sonoclot gave additional information to routine coagulation studies, correctly indicated insufficient haemostasis and predicted a positive outcome. Also, plasma exchanges and platelet transfusions could be controlled in the management of DIC.


This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
F. Forestier, S. Belisle, C. Contant, F. Harel, G. Janvier, and J.-F. Hardy
Reproductibilite et interchangeabilite du Thromboelastographe(R), Sonoclot(R) et du temps de coagulation active (Hemochron(R)), en chirurgie cardiaque : [Reproducibility and interchangeability of the Thromboelastograph(R), Sonoclot(R) and Hemochron(R) activated coagulation time in cardiac surgery]
Can J Anesth, October 1, 2001; 48(9): 902 - 910.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. G. Pivalizza, P. J. Pivalizza, S. Kee, L. I. Gottschalk, P. Szmuk, and D. C. Abramson
Sonoclot Analysis in Healthy Children
Anesth. Analg., April 1, 2001; 92(4): 904 - 906.
[Abstract] [Full Text] [PDF]


Home page
Clin. Microbiol. Rev.Home page
M. van Deuren, P. Brandtzaeg, and J. W. M. van der Meer
Update on Meningococcal Disease with Emphasis on Pathogenesis and Clinical Management
Clin. Microbiol. Rev., January 1, 2000; 13(1): 144 - 166.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. Konrad, T. Markl, G. Schuepfer, H. Gerber, and M. Tschopp
The Effects of In Vitro Hemodilution with Gelatin, Hydroxyethyl Starch, and Lactated Ringer’s Solution on Markers of Coagulation: An Analysis Using SONOCLOTTM
Anesth. Analg., March 1, 1999; 88(3): 483 - 483.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the Canadian Anesthesiologists' Society.