CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Standl, T.
Right arrow Articles by Schulte am Esch, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Standl, T.
Right arrow Articles by Schulte am Esch, J.

Canadian Journal of Anesthesia, Vol 42, 701-705, Copyright © 1995 by Canadian Anesthesiologists' Society


ARTICLES

A directional needle improves effectiveness and reduces complications of microcatheter continuous spinal anaesthesia

T Standl, S Eckert, I Rundshagen and J Schulte am Esch
Department of Anaesthesiology, University Hospital Eppendorf, Hamburg, Germany.

The present prospective randomized study compares the impact of two different spinal needle designs--non-directional versus directional--on the effectiveness of continuous spinal anaesthesia provided via a microcatheter in orthopaedic patients. Using the midline approach, a 28-gauge spinal catheter was inserted either through a 22-gauge Quincke needle (non-directional, Group 1, n = 21) or a 22-gauge Sprotte needle (directional, Group 2, n = 21) under standardized conditions. The incidence of technical difficulties and postoperative complaints, onset time of analgesia at the level of T10 and dose requirement of plain bupivacaine 0.5% were recorded. Postoperatively, the subarachnoid position of the catheters was radiographically evaluated. There was a higher incidence of technical problems during catheter insertion in Group 1 compared with Group 2 (71% vs 19%, P < 0.05). Onset time of analgesia was shorter (P < 0.05) and anaesthetic dose requirement was lower in patients in Group 2 than in Group 1. While 40% of the catheters were found in a caudal position in Group 1, all catheters were in a cranial position or at the level of the puncture site in Group 2 (P < 0.05). There was no difference in the incidence of postoperative complaints between the groups. The faster onset of analgesia and lower dose requirement of local anaesthetics associated with a lower incidence of technical problems suggest that there is greater effectiveness and safety when microcatheters are inserted using directional needles rather than non-directional needles.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the Canadian Anesthesiologists' Society.