CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Matsukawa, T.
Right arrow Articles by Kumazawa, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Matsukawa, T.
Right arrow Articles by Kumazawa, T.

Canadian Journal of Anesthesia, Vol 43, 1224-1228, Copyright © 1996 by Canadian Anesthesiologists' Society


ARTICLES

A comparison of four infrared tympanic thermometers with tympanic membrane temperatures measured by thermocouples

T Matsukawa, M Ozaki, K Hanagata, H Iwashita, T Miyaji and T Kumazawa
Department of Anaesthesia, Yamanashi Medical University, Japan. takashim@res.yamanashi-med.ac.jp

PURPOSE: To compare measurements made with four infrared tympanic thermometers (Genius, Thermopit, Quickthermo, and Thermoscan) with those recorded from thermocouples positioned in the contralateral ear. METHODS: Four tympanic thermometers were evaluated in 50 healthy volunteers (12 female and 38 male). Temperatures were measured, in random order, at the right tympanic membrane four times and the highest temperature was considered to be the true value measured by each thermometer. The control temperature was measured at the left tympanic membrane using Mon-a-Therm thermocouples. RESULTS: The tympanic membrane temperature measured by Genius correlated best with the Mon-a-therm measurement (TM) (r = 0.74). The tympanic membrane temperatures measured by Thermopit, Quickthermo, and Thermoscan correlated moderately with TM (r = 0.56, 0.63, and 0.58, respectively). Mean differences between TM and each temperature (TG, TTP, TQ, and TTS) were -0.3, 0.73, 0.42, and -0.3 degrees C, respectively. Likewise standard deviations were 0.33, 0.37, 0.35, and 0.35. CONCLUSION: We conclude that all but the Thermopit (TTP) are similarly useful for the management of patients during anaesthesia.


This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
M. Bock, U. Hohlfeld, K. von Engeln, P. A. Meier, J. Motsch, and A. J. Tasman
The accuracy of a new infrared ear thermometer in patients undergoing cardiac surgery: [La precision d'un nouveau thermometre auriculaire infrarouge chez des patients de cardiochirurgie]
Can J Anesth, December 1, 2005; 52(10): 1083 - 1087.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
C. Peterson
Exercise in 94{degrees}F Water for a Patient With Multiple Sclerosis
Physical Therapy, April 1, 2001; 81(4): 1049 - 1058.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Boysen and H. Christensen
Stroke Severity Determines Body Temperature in Acute Stroke
Stroke, February 1, 2001; 32(2): 413 - 417.
[Abstract] [Full Text]


Home page
Anesth. Analg.Home page
S. Mantha, M. F. Roizen, L. A. Fleisher, R. Thisted, and J. Foss
Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Anesth. Analg., March 1, 2000; 90(3): 593 - 602.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Canadian Anesthesiologists' Society.