CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zamora, J. E.
Right arrow Articles by Crossan, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zamora, J. E.
Right arrow Articles by Crossan, M. L.

Canadian Journal of Anesthesia, Vol 43, 347-352, Copyright © 1996 by Canadian Anesthesiologists' Society


ARTICLES

Haemodynamic consequences and uterine contractions following 0.5 or 1.0 litre crystalloid infusion before obstetric epidural analgesia

JE Zamora, OP Rosaeg, MP Lindsay and ML Crossan
Department of Anaesthesia, Ottawa Civic Hospital, University of Ottawa, Ontario, Canada.

PURPOSE: The efficacy of infusion of 0.5 L and 1.0 L Ringer's lactate (LR) to prevent hypotension during induction of obstetric analgesia was studied. The effect of the different fluid boluses on fetal heart rate (FHR) and frequency of uterine contractions were also determined. METHODS: Ninety-two ASA 1-2 parturients were randomized to receive 0.5 L (Group 1) and 1.0 L (Group 2) LR immediately before incremental epidural injections with lidocaine to achieve T10 sensory block. Systolic blood pressure (SBP) was measured with an automated BP cuff every two minutes for 30 min after infusion of fluid bolus. Fetal heart rate monitoring and tocometry were used continuously. The number of uterine contractions were recorded 30 min before and 60 min after i.v. bolus. RESULTS: The SBP decreased in both groups, but there was no difference between groups in mean SBP or maternal heart rate. The incidence of hypotension (SBP < 90 mmHg or decrease of 20%) was 4% in both groups. The FHR record of a patient in Group 1 showed a single late deceleration, and a decrease in beat-to-beat variability occurred in one patient in Group 2. A decrease in the frequency of uterine contractions of two or more contractions per 30 min was noted more frequently in Group 2 (P < 0.05). The duration of iv bolus was longer in Group 2 than Group 1 (18.8 +/- 4.3 min vs 12.3 +/- 4.5 min, P < 0.01). CONCLUSION: Administration of 1.0 L LR i.v. does not provide added protection against maternal hypotension, and is associated with delay in providing pain relief and a risk of decreasing uterine contraction frequency.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Canadian Anesthesiologists' Society.