CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Le Merre, C.
Right arrow Articles by Balmes, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Le Merre, C.
Right arrow Articles by Balmes, P.

Canadian Journal of Anesthesia, Vol 43, 672-677, Copyright © 1996 by Canadian Anesthesiologists' Society


ARTICLES

Pulmonary gas exchange capacity is reduced during normovolaemic haemodilution in healthy human subjects

C Le Merre, M Dauzat, P Poupard, R Targhetta, C Fabre, S Bouges, JJ Eledjam and P Balmes
Pneumology Unit, University Hospital, Nimes, France.

PURPOSE: To test the hypothesis that a physiological compensatory mechanism maintains respiratory gas exchange during normovolaemic haemodilution. METHODS: Pulmonary gas exchange capacity was evaluated in seven healthy subjects by measuring the lung diffusion of carbon monoxide (DLCO). During the measurement, various breath-holding times, inspiratory volumes, and sitting or supine positions, were randomly selected in an attempt to alter pulmonary capillary perfusion. KCO was calculated as the percentage of theoretical values of the ratio of DLCO by alveolar volume and normalized by sex, age, and height. Normovolaemic haemodilution (NH) was performed by bleeding an average blood volume of 1 L with simultaneous Dextran 60 replacement to obtain an haematocrit below 35%. RESULTS: After NH, haemoblogin concentration [Hb] decreased from 14.94 +/- 0.96 to 12.5 +/- 0.98 g.dl-1 (P < 0.001). KCO decreased (P < 0.02) but remained closely correlated to [Hb] at every lung volume (P < 0.02). Breathholding time and body position had no effect. CONCLUSION: Moderate NH impairs pulmonary gas exchange capacity in awake, resting healthy subjects. There is no evidence of any compensatory mechanism since the KCO vs [Hb] relationship is unchanged.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Canadian Anesthesiologists' Society.