CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wahba, R. W.
Right arrow Articles by Tessler, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wahba, R. W.
Right arrow Articles by Tessler, M. J.

Canadian Journal of Anesthesia, Vol 43, 862-866, Copyright © 1996 by Canadian Anesthesiologists' Society


ARTICLES

Misleading end-tidal CO2 tensions

RW Wahba and MJ Tessler
Department of Anaesthesia, SMBD-Jewish General Hospital, Montreal, Canada.

PURPOSE: The aim of this study was to determine if the literature supported the assumption that the values and changes in end-tidal PCO2 (PETCO2) during anaesthesia accurately reflect the values and changes in arterial PCO2 (PaCO2) is tenable. METHODS: The information was obtained by (a) a Medline literature search and the appropriate references quoted in the list generated; (b) appropriate abstracts in recent issues of the annual meeting supplements of Anesth Analg, Anesthesiology, Br J Anaesth and Can J Anaesth. We specifically sought information obtained during major operations, in sick patients, and reports of serial measurements. The information obtained is summarized in graphic form, with a discussion of the mechanisms and clinical implications. RESULTS: (1) Patients with systemic disease, or when placed in the lateral position, or with haemodynamic instability have an increased Pa-PETCO2 gradient. The values during surgery are probably due to marked alterations of ventilation: perfusion relationships. (2) In a number of reports, the gradient varied widely during the procedure. (3) The gradient may be reduced due to an alteration of the configuration of the alveolar plateau. (4) The magnitude and direction of change in PaCO2 and PETCO2 can be disproportionate and in the opposite direction. CONCLUSION: End-tidal PCO2 is often not indicative of PaCO2. Also, changes in PETCO2 do not always accurately indicate the direction and extent of the change in PaCO2.


This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
J. Hudcova and R. Schumann
Arterial to end-tidal CO2 gradient reversal during laparoscopic pheochromocytoma resection: [Le renversement du gradient du CO2 arteriel/tele-expiratoire pendant la resection laparoscopique d'un pheochromocytome]
Can J Anesth, April 1, 2006; 53(4): 409 - 412.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Engoren, M. Plewa, D. O'Hara, and J. A. Kline
Evaluation of Capnography Using a Genetic Algorithm To Predict PaCO2
Chest, February 1, 2005; 127(2): 579 - 584.
[Abstract] [Full Text] [PDF]


Home page
Emerg. Med. J.Home page
C Yosefy, E Hay, Y Nasri, E Magen, and L Reisin
End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting
Emerg. Med. J., September 1, 2004; 21(5): 557 - 559.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. Helm, R. Schuster, J. Hauke, and L. Lampl
Tight control of prehospital ventilation by capnography in major trauma victims
Br. J. Anaesth., March 1, 2003; 90(3): 327 - 332.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Canadian Anesthesiologists' Society.