CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rudston-Brown, B.
Right arrow Articles by Phang, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rudston-Brown, B.
Right arrow Articles by Phang, P. T.

Canadian Journal of Anesthesia, Vol 44, 1102-1107, Copyright © 1997 by Canadian Anesthesiologists' Society


ARTICLES

Venous gas embolism--a comparison of carbon dioxide and helium in pigs

B Rudston-Brown, PN Draper, B Warriner, KR Walley and PT Phang
Division of General Surgery, St. Paul's Hospital, Vancouver, British Columbia, Canada.

PURPOSE: The use of helium for insufflation during laparoscopic surgery avoids hypercarbia and acidosis associated with absorbed CO2, but the effects of helium gas embolism are unknown. We compared the effects of CO2 with He gas embolism on survival, haemodynamic variables, oxygenation, and ventilation in pigs. METHODS: Anaesthetized juvenile pigs were given progressively larger boluses of either CO2 (n = 5) or He (n = 4) into the right atrium. Measurements of haemodynamic variables, oxygenation, and PETCO2 were made before and after each gas injection. RESULTS: All animals survived injection of 300 ml CO2 while no animal survived more than 120 ml He (P < 0.01). Mean arterial pressure decreased more after 60 ml He (99 +/- 14 to 44 +/- 20 mmHg) than after 60 ml CO2 (110 +/- 12 to 88 +/- 14 mmHg, P < 0.001). Cardiac output did not change at any injection volume. The PETCO2 decreased more after 60 ml He (30 +/- 2 to 3 +/- 6 mmHg) than after 60 ml CO2 (35 +/- 3 to 30 +/- 3 mmHg, P < 0.001). Only the He group showed a decrease in PaO2 (190 +/- 51 to 68 +/- 22 mmHg at 60 ml, P < 0.05). CONCLUSION: Helium gas embolism has a greater deleterious effect than CO2 gas embolism on survival, MAP, PETCO2, and PaO2. These different effects of gas embolism should be recognized when considering the use of helium or other insoluble gases for abdominal laparoscopic insufflation.


This article has been cited by other articles:


Home page
Hum ReprodHome page
C. R. Molinas and P. R. Koninckx
Hypoxaemia induced by CO2 or helium pneumoperitoneum is a co-factor in adhesion formation in rabbits
Hum. Reprod., August 1, 2000; 15(8): 1758 - 1763.