CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gueugniaud, P. Y.
Right arrow Articles by Petit, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gueugniaud, P. Y.
Right arrow Articles by Petit, P.

Canadian Journal of Anesthesia, Vol 44, 745-750, Copyright © 1997 by Canadian Anesthesiologists' Society


ARTICLES

Continuous oesophageal aortic blood flow echo-Doppler measurement during general anaesthesia in infants

PY Gueugniaud, R Muchada, M Moussa, D Haro and P Petit
Department of Anaesthesiology, Edouard Herriot Hospital, Lyon, France.

PURPOSE: Invasive haemodynamic monitoring during general anaesthesia in infants is usually limited to very high risk operations, such as cardiac surgery. Nevertheless, different surgical procedures and/or anaesthetic techniques justify additional monitoring for children, as for adults. The aim of this preliminary study was to evaluate the feasibility of using a new echo-Doppler device (Dynemo 3000) capable of measuring continuous aortic blood flow during general anaesthesia in infants. METHODS: Aortic blood flow (ABF) was measured with a small oesophageal probe designed for newborns and infants. The aortic flowmeter was connected with satellite devices to visualise the haemodynamic profile which included ABF, pre-ejection period (PEPi), left ventricular ejection time (LVETi), mean arterial pressure, heart rate, stroke volume and systemic vascular resistance. Twelve infants, aged 8-26 mo, undergoing surgery under general anaesthesia were successively included in the evaluation of this device. Isoflurane (1% end-expired concentration) was introduced to maintain anaesthesia after induction with halothane, midazolam, fentanyl and atracurium. RESULTS: Correct positioning of the probe was easily obtained in all cases and the recording quality was excellent, whatever the operative position. Recordings of haemodynamic data showed some myocardial depression from isoflurane: decreased ABF (indexed to body surface area) and lengthened PEP/LVET (2.24 +/- 0.53 L.min-1.m-2 and 0.32 +/- 0.05 respectively, before introduction of isoflurane and 1.71 +/ 0.53 L.min-1.m-2 (P = 0.027) and 0.39 +/- 0.06 (P = 0.007) with isoflurane). CONCLUSION: These preliminary results suggest that this continuous ABF echo-Doppler device may be valuable for peri anaesthetic monitoring in infants.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
A. Monsel, A. Salvat-Toussaint, P. Durand, V. Haas, C. Baujard, P. Rouleau, S. El Aouadi, D. Benhamou, and K. Asehnoune
The Transesophageal Doppler and Hemodynamic Effects of Epidural Anesthesia in Infants Anesthetized with Sevoflurane and Sufentanil
Anesth. Analg., July 1, 2007; 105(1): 46 - 50.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. Larousse, K. Asehnoune, B. Dartayet, P. Albaladejo, A.-M. Dubousset, F. Gauthier, and D. Benhamou
The Hemodynamic Effects of Pediatric Caudal Anesthesia Assessed by Esophageal Doppler
Anesth. Analg., May 1, 2002; 94(5): 1165 - 1168.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the Canadian Anesthesiologists' Society.