CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Colbert, S. A.
Right arrow Articles by Moriarty, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Colbert, S. A.
Right arrow Articles by Moriarty, D. C.

Canadian Journal of Anesthesia, Vol 45, 23-27, Copyright © 1998 by Canadian Anesthesiologists' Society


ARTICLES

The laryngeal mask airway reduces blood flow in the common carotid artery bulb

SA Colbert, DM O'Hanlon, F Flanagan, R Page and DC Moriarty
Department of Anaesthesia, Mater Misericordiae Hospital, Dublin, Ireland.

PURPOSE: The introduction of the laryngeal mask airway (LMA) has had a major impact on anaesthetic practice in the last ten years. Previous authors have demonstrated pressures equivalent to mean arterial blood pressure within the cuff of the LMA. This study examined the effects of cuff inflation on the cross sectional area, flow and velocity of blood flow at the level of the carotid sinus. METHODS: Seventeen patients scheduled to have LMAs inserted as part of routine anaesthetic management were recruited into the study. Measurements of the common carotid artery bulb area, peak velocity and blood flow were performed upon LMA cuff inflation and deflation using a 5 MHz pulse wave Doppler probe. RESULTS: Deflation of the cuff resulted in an increase in the cross sectional area (from 0.58 +/- 0.05 to 0.64 +/- 0.04 cm2; P < 0.005), an increase in blood flow (from 65.6 +/- 5.6 to 73.9 +/- 5.6 cm3.sec-1; P < 0.05) and a slight but non significant increase in velocity of blood flow. CONCLUSION: This study demonstrates that inflation of the cuff on the LMA results in a decrease in carotid bulb cross sectional area which results in a decrease in blood flow.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
R. J. Lenoir
Venous congestion of the neck; its relation to laryngeal mask cuff pressures
Br. J. Anaesth., September 1, 2004; 93(3): 476 - 477.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the Canadian Anesthesiologists' Society.