CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tobias, J. D.
Right arrow Articles by Helikson, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tobias, J. D.
Right arrow Articles by Helikson, M. A.

Canadian Journal of Anesthesia, Vol 45, 81-83, Copyright © 1998 by Canadian Anesthesiologists' Society


ARTICLES

Monitoring of pH and PCO2 in children using the Paratrend 7 in a peripheral vein

JD Tobias, DJ Meyer Jr and MA Helikson
Department of Child Health, University of Missouri, Columbia 65212, USA.

PURPOSE: To determine the accuracy of the Paratrend 7 monitor inserted into a peripheral vein in providing continuous measurements of PCO2 and pH in children with respiratory failure. METHODS: In a prospective, case series at a University based PICU in a tertiary referral hospital and following informed consent, the Paratrend 7 intra-arterial blood gas monitoring system was inserted through a peripheral intravenous cannula. When clinically indicated, an arterial blood gas (ABG) was obtained. The values of pH and PCO2 from the Paratrend 7 and the ABG were compared using linear regression analysis and Bland-Altman analysis. RESULTS: Seventeen ABGs were obtained in the 4 patients. PaCO2 ranged from 29 to 51 mmHg and the pH values from 7.16 to 7.50. Linear regression analysis for the: Paratrend 7 pH vs the ABG pH resulted in an r = 0.9678 and an r2 = 0.9367 (P < 0.0001). Linear regression analysis for the Paratrend 7 CO2 vs ABG CO2 resulted in an r = 0.8273 and an r2 = 0.6845 (P = 0.01). Using a Bland and Altman analysis, the bias +/- precision of the PCO2 values was 3 +/- 1.4 and 0.036 +/- 0.02 for the pH values. CONCLUSION: The pH and PCO2 values obtained from the Paratrend 7 monitor provide a clinically acceptable correlation with arterial values.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
M. Ganter and A. Zollinger
Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device
Br. J. Anaesth., September 1, 2003; 91(3): 397 - 407.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Mantha, M. F. Roizen, L. A. Fleisher, R. Thisted, and J. Foss
Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Anesth. Analg., March 1, 2000; 90(3): 593 - 602.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. L. Williams, K. L. Hildebrand, S. A. McCormick, and M. J. Bedel
The Effect of Intravenous Lactated Ringer's Solution Versus 0.9% Sodium Chloride Solution on Serum Osmolality in Human Volunteers
Anesth. Analg., May 1, 1999; 88(5): 999 - 1003.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the Canadian Anesthesiologists' Society.