CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamakage, M.
Right arrow Articles by Namiki, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamakage, M.
Right arrow Articles by Namiki, A.

Canadian Journal of Anesthesia, Vol 45, 993-996, Copyright © 1998 by Canadian Anesthesiologists' Society


ARTICLES

The usefulness of celite-activated thromboelastography for evaluation of fibrinolysis

M Yamakage, N Tsujiguchi, S Kohro, H Tsuchida and A Namiki
Department of Anesthesiology, Sapporo Medical University, School of Medicine, Hokkaido, Japan. yamakage@sapmed.ac.jp

PURPOSE: Although thromboelastography is useful for measuring both coagulability and fibrinolysis, it takes about two hours to measure all parameters including fibrinolytic rate. The present study aimed to investigate the usefulness of celite-activated thromboelastography (TEGc) to evaluate fibrinolytic status in non-cardiac surgery. METHODS: Whole blood samples were obtained from 30 patients for non-cardiac surgery, and used for measurements of both native TEG (TEGn) and TEGc. The final concentration of 1% (w/v) celite was used for TEGc. RESULTS: Time for measurement of the fibrinolytic rate (FR) of TEGc in patients (56.7 +/- 4.0 min) was less than half that of FR of TEGn (123.3 +/- 15.6 min) (P < 0.05), suggesting a more rapid assessment of fibrinolytic status. A linear relationship was observed between FR values of TEGc and those of TEGn (r = 0.93, P < 0.0001), suggesting the usefulness of the fibrinolytic parameter of TEGc. CONCLUSION: TEGc is a useful technique for a more rapid assessment of fibrinolytic status.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. M. Goobie, S. G. Soriano, D. Zurakowski, F. X. McGowan, and M. A. Rockoff
Hemostatic Changes in Pediatric Neurosurgical Patients as Evaluated by Thrombelastograph(R)
Anesth. Analg., October 1, 2001; 93(4): 887 - 892.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
S. A. Leonard, A. Lydon, M. Walsh, C. Fleming, J. Boylan, and G. D. Shorten
Does prior administration of enoxaparin influence the effects of levobupivacaine on blood clotting? Assessment using the Thrombelastograph(R)
Br. J. Anaesth., June 1, 2001; 86(6): 808 - 813.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
G. Ekback, K. Axelsson, L. Ryttberg, B. Edlund, J. Kjellberg, J. Weckstrom, O. Carlsson, and U. Schott
Tranexamic Acid Reduces Blood Loss in Total Hip Replacement Surgery
Anesth. Analg., October 1, 2000; 91(5): 1124 - 1130.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. E. Miller, N. A. Guzzetta, S. R. Tosone, and J. H. Levy
Rapid Evaluation of Coagulopathies After Cardiopulmonary Bypass in Children Using Modified Thromboelastography
Anesth. Analg., June 1, 2000; 90(6): 1324 - 1330.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the Canadian Anesthesiologists' Society.