CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pang, W. W.
Right arrow Articles by Huang, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pang, W. W.
Right arrow Articles by Huang, M. H.

Canadian Journal of Anesthesia, Vol 45, 785-788, Copyright © 1998 by Canadian Anesthesiologists' Society


ARTICLES

Negative pressure pulmonary oedema induced by direct suctioning of endotracheal tube adapter

WW Pang, DP Chang, CH Lin and MH Huang
Department of Anesthesia and Surgery, Show-Chwan Memorial Hospital, Changhua, Taiwan, R.O.C.

PURPOSE: Negative pressure pulmonary oedema (NPPE) is a well-recognized but rare complication secondary to upper airway obstruction such as laryngeal spasm during emergence from general anaesthesia. Cauterization of the second and third thoracic sympathetic ganglia is a treatment for hyperhidrosis of the hands. We report a case of NPPE induced by direct suctioning of the endotracheal tube adapter during thoracic sympathetic ganglionectomy without recognized upper airway obstruction. CLINICAL FEATURES: A 19-yr-old otherwise healthy, non-smoking man was scheduled for elective bilateral chest endoscopic ablation of the second and third thoracic sympathetic ganglion for hyperhidrosis of the hands under general anaesthesia. To view and cauterize the ganglion with the endoscope, the surgeon requested cessation of positive pressure ventilation. As the surgeon could not satisfactorily visualize the target ganglia, he requested brief application of wall suction via the ETT tube adapter. A pressure of -100 mmHg was generated which lasted for three to four seconds. The goal was to reduce further the lung volume by increasing the pneumothorax produced by the endoscope. The patient developed negative pressure pulmonary oedema without upper airway obstruction. CONCLUSION: This case demonstrated that intrathoracic negative pressure generated by direct ETT adapter suctioning may produce pulmonary oedema similar to that induced by laryngeal spasm during the emergence of general anaesthesia.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. G. Memtsoudis, P. Rosenberger, and N. Sadovnikoff
Chest Tube Suction-Associated Unilateral Negative Pressure Pulmonary Edema in a Lung Transplant Patient
Anesth. Analg., July 1, 2005; 101(1): 38 - 40.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
S. Hannania, M. Barak, and Y. Katz
Unilateral Negative-Pressure Pulmonary Edema in an Infant During Bronchoscopy
Pediatrics, May 1, 2004; 113(5): e501 - e503.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
K. Quader, P. H. Manninen, and J. K.T. Lai
Pulmonary edema in the neuroradiology suite: a diagnostic dilemma
Can J Anesth, March 1, 2001; 48(3): 308 - 312.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the Canadian Anesthesiologists' Society.