CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dennehy, K. C.
Right arrow Articles by Wynands, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dennehy, K. C.
Right arrow Articles by Wynands, J. E.

Canadian Journal of Anesthesia, Vol 46, 56-60, Copyright © 1999 by Canadian Anesthesiologists' Society


ARTICLES

Profound hypoxemia during treatment of low cardiac output after cardiopulmonary bypass

KC Dennehy, JY Dupuis, HJ Nathan and JE Wynands
Department of Cardiac Anesthesia, University of Ottawa Heart Institute, HIRC, Ontario, Canada.

PURPOSE: To illustrate the multiple causes of hypoxemia to be considered following cardiopulmonary bypass and how therapy given to improve oxygen delivery may have contributed to a decrease in arterial oxygen saturation to life-threatening levels. CLINICAL FEATURES: A 61 yr old man with severe mitral regurgitation and chronic obstructive lung disease underwent surgery for mitral valve repair. A pulmonary artery catheter with the capacity to measure cardiac output and mixed venous oxygen saturation (SvO2) continuously was used. Two unsuccessful attempts were made to repair the valve which was finally replaced, requiring cardiopulmonary bypass of 317 min. Dobutamine 5 micrograms.kg-1.min-1 and sodium nitroprusside 1 microgram.kg-1.min-1 were used to increase cardiac output. Soon after, the SvO2 decreased progressively from 55 to 39%. The patient became cyanotic with a PaO2 of 39 mmHg. Sodium nitroprusside was stopped and amrinone 100 mg bolus followed by 10 micrograms.kg-1.min-1 was given in addition to adding PEEP to the ventilation. With these measures PaO2 could be maintained of safe levels but PEEP and high inspired oxygen concentrations were needed postoperatively until the trachea could be extubated on the third postoperative day. CONCLUSION: The profound hypoxemia in this case was likely due to a combination of intra- and extrapulmonary shunt, both augmented by sodium nitroprusside. The desaturation of mixed venous blood amplified the effect of these shunts in decreasing arterial oxygen saturation. The interaction of these factors are analyzed in this report.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the Canadian Anesthesiologists' Society.