T Asai, H Matsumoto and K Shingu
Department of Anaesthesiology, Kansai Medical University, Osaka, Japan. asait@takii.kmu.ac.jp
PURPOSE: To report successful awake insertion of the intubating laryngeal mask (Fastrach) and subsequent tracheal intubation through it, in a patient with predicted difficult tracheal intubation, due to limited mouth opening, and difficult ventilation through a facemask, due to a large mass at the corner of the mouth. CLINICAL FEATURES: A 53-yr-old woman with a large post-gangrenous mass on the right cheek to the angle of the mouth was scheduled for its resection. The right side of her face was damaged by a bomb attack followed by cancrum oris 50 yr ago. The distance between the incisors during maximum mouth opening was 2 cm and that between the gums on the right side < 1 cm. After preoxygenation and 50 micrograms fentanyl and 30 mg propofol i.v., propofol was infused at 2 mg.kg-1.hr-1. Lidocaine, 8%, was sprayed on the oropharynx. A #4 intubating laryngeal mask was inserted with a little difficulty. A fibrescope was passed through a 7.5-mm ID RAE tracheal tube, and the combination was easily passed through the laryngeal mask into the trachea. General ansthesia was then induced. Finally, the intubating laryngeal mask was removed, while the RAE tube was being stabilized using an uncuffed 6.0-mm ID tracheal tube. CONCLUSION: Awake tracheal intubation through the intubating laryngeal mask is a useful technique in patients with limited mouth opening in whom ventilation via a facemask is expected to be difficult.
This article has been cited by other articles:
![]() |
F. Hamard, M. Ferrandiere, X. Sauvagnac, J. C. Mangin, J. Fusciardi, C. Mercier, and M. Laffon La sedation au propofol permet l'intubation difficile vigile avec le masque larynge FastrachTM: [Propofol sedation allows awake intubation of the difficult airway with the FastrachTM LMA] Can J Anesth, April 1, 2005; 52(4): 421 - 427. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. S. Joo, M. T. Kataoka, R. J.B. Chen, J. Doyle, and C. D. Mazer PVC tracheal tubes exert forces and pressures seven to ten times higher than silicone or armoured tracheal tubes - an in vitro study: [Les tubes tracheaux de PVC exercent des forces et des pressions de sept a dix fois plus elevees que les tubes en silicone ou les tubes armes - une etude in vitro] Can J Anesth, November 1, 2002; 49(9): 986 - 989. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Preis and I. Preis Removal of the connector on the laryngeal mask airway provides a useful alternative to the intubating laryngeal mask : [Le retrait du connecteur du masque larynge permet une utilisation equivalente au masque larynge d'intubation] Can J Anesth, June 1, 2001; 48(6): 600 - 603. [Abstract] [Full Text] |
||||
![]() |
C. Preis, C. Czerny, I. Preis, and M. Zimpfer Variations in ILMA external diameters: another cause of device failure Can J Anesth, September 1, 2000; 47(9): 886 - 889. [Abstract] [Full Text] [PDF] |
||||