CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Takenaka, I.
Right arrow Articles by Shigematsu, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takenaka, I.
Right arrow Articles by Shigematsu, A.

Canadian Journal of Anesthesia, Vol 46, 226-231, Copyright © 1999 by Canadian Anesthesiologists' Society


ARTICLES

Fibreoptic assessment of laryngeal aperture in patients with difficult laryngoscopy

I Takenaka, K Aoyama, T Kadoya, T Sata and A Shigematsu
Department of Anesthesiology, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.

PURPOSE: To determine the relationship between the area of the laryngeal aperture (LA) seen fibreoptically during laryngoscopy and the difficulty of tracheal intubation in patients with difficult laryngoscopy METHODS: In 587 adult patients after induction of general anesthesia and muscle relaxation, the best laryngoscopic view of the larynx using a Macintosh 3 blade was classified according to Cormack. When the LA could not be seen, with laryngoscope blade in place, the LA view provided by a fibreoptic bronchoscope (FOB)-camera passed nasally was photographed. Then, the laryngoscopist attempted to intubate the trachea using the Macintosh blade. Tracheal intubation requiring more than three attempts was defined as difficult. After the third attempt, the trachea was intubated orally aided by FOB. The LA view after jaw thrust during FOB-aided intubation was photographed. RESULTS: Laryngoscopy was difficult in 17 of 587 patients. In four, intubation was difficult. In the remaining 13 patients the trachea was easy to intubate. The LA area obtained by the FOB in the difficult group (median, 0.19; intra-quartile range, 0.14 to 0.39 cm2) was smaller than that in the easy group (2.43; 1.84 to 2.93 cm2)(P = 0.003). In contrast, the LA area provided by jaw thrust during the FOB-aided intubation in the difficult group (2.28; 1.99 to 2.73 cm2) was similar to that during laryngoscopy in the easy group. CONCLUSION: Inability of the laryngoscope to provide an adequate LA view is one cause of difficult intubation with the Macintosh laryngoscope in patients with difficult laryngoscopy.


This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
I. Takenaka, K. Aoyama, M. Nakamura, H. Fukuyama, Y. Urakami, Y. Takenaka, and T. Kadoya
Oral styletted intubation under video control in a patient with a large mobile glottic tumour and a difficult airway : [L'intubation orale avec un stylet videoguide chez un patient presentant une importante tumeur mobile de la glotte et une intubation difficile]
Can J Anesth, February 1, 2002; 49(2): 203 - 206.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. D. Mentzelopoulos, C. N. Romana, D. S. Corolanoglou, M. J. Tzoufi, and E. A. Karamichali
Balloon Versus Conventional Laryngoscopy: A Comparison of Laryngoscopic Findings and Intubation Difficulty
Anesth. Analg., December 1, 2000; 91(6): 1513 - 1519.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
K. Aoyama, I. Takenaka, E. Nagaoka, T. Kadoya, N. Saruki, and S. Saito
Jaw Thrust Maneuver for Endotracheal Intubation Using a Fiberoptic Stylet Response
Anesth. Analg., June 1, 2000; 90(6): 1457 - 1458.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the Canadian Anesthesiologists' Society.