CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Takahashi, S.
Right arrow Articles by Tanaka, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takahashi, S.
Right arrow Articles by Tanaka, M.

Canadian Journal of Anesthesia, Vol 46, 433-438, Copyright © 1999 by Canadian Anesthesiologists' Society


ARTICLES

Reduced efficacy of simulated epidural test doses in sevoflurane-anesthetized adults

S Takahashi and M Tanaka
Department of Anesthesia, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan.

PURPOSE: To determine the hemodynamic responses to, and the efficacy of epinephrine-containing epidural test doses, during sevoflurane anesthesia, based on the conventional heart rate (HR) increase > or = 20 beats x min(-1), the modified HR increase if > or = 10 beats x min(-1), and the systolic blood pressure (SBP) increase 15 mmHg criteria. METHODS: One hundred and twenty patients were randomised to receive sevoflurane 0.5, 1 or 2% end-tidal (n = 40 each) and nitrous oxide 67% in oxygen after tracheal intubation. Each group of patients was further divided into groups receiving 3 ml lidocaine 1.5% plus 15 microg epinephrine (1:200,000) i.v., or 3 ml normal saline (n = 20 each). The HR and SBP were monitored for four minutes after injection of the study drug. RESULTS: Intravenous injection of the test dose produced HR increases > or = 20 beats x min(-1) in 18 (90%), 16 (80%) and 14 (70%) patients at sevoflurane concentrations at 0.5, 1 and 2%, respectively, while those receiving saline developed no HR changes. Based on the modified HR criterion, sensitivity, specificity, and positive and negative predictive values were all 100% under sevoflurane concentrations of 0.5 and 1%, but not 2%. On the other hand, all patients in the test dose groups and none in the saline groups developed SBP > or = 15 mmHg, ensuring 100% efficacy based on the conventional SBP criterion under all sevoflurane concentrations studied. In all patients receiving the intravenous test dose, peak HR occurred 30-45 sec earlier than that of SBP. CONCLUSION: During stable sevoflurane anesthesia, peak HR increase > or = 10 beats x min(-1) should be regarded as a positive response with end-tidal sevoflurane concentration < or = 1%, and peak SBP increase > or = 15 mmHg is applicable at sevoflurane concentrations between 0.5 and 2%.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. Guay
The epidural test dose: a review.
Anesth. Analg., March 1, 2006; 102(3): 921 - 929.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
H. A. Mowafi
The Efficacy of Plethysmographic Pulse Wave Amplitude as an Indicator for Intravascular Injection of Epinephrine-Containing Epidural Test Dose in Anesthetized Adults
Anesth. Analg., November 1, 2005; 101(5): 1506 - 1511.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
H. A. Mowafi
Digital Skin Blood Flow as an Indicator for Intravascular Injection of Epinephrine-Containing Simulated Epidural Test Dose in Sevoflurane-Anesthetized Adults
Anesth. Analg., August 1, 2005; 101(2): 584 - 588.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Tanaka, T. Goyagi, T. Kimura, and T. Nishikawa
The Efficacy of Hemodynamic and T wave Criteria for Detecting Intravascular Injection of Epinephrine Test Doses in Anesthetized Adults: A Dose-Response Study
Anesth. Analg., October 1, 2000; 91(5): 1196 - 1202.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Tanaka and T. Nishikawa
Aging Reduces the Efficacy of the Simulated Epidural Test Dose in Anesthetized Adults
Anesth. Analg., September 1, 2000; 91(3): 657 - 661.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the Canadian Anesthesiologists' Society.