| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Canadian Journal of Anesthesia, Vol 46, 433-438, Copyright © 1999 by Canadian Anesthesiologists' Society
ARTICLES |
S Takahashi and M Tanaka
Department of Anesthesia, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan.
PURPOSE: To determine the hemodynamic responses to, and the efficacy of epinephrine-containing epidural test doses, during sevoflurane anesthesia, based on the conventional heart rate (HR) increase > or = 20 beats x min(-1), the modified HR increase if > or = 10 beats x min(-1), and the systolic blood pressure (SBP) increase 15 mmHg criteria. METHODS: One hundred and twenty patients were randomised to receive sevoflurane 0.5, 1 or 2% end-tidal (n = 40 each) and nitrous oxide 67% in oxygen after tracheal intubation. Each group of patients was further divided into groups receiving 3 ml lidocaine 1.5% plus 15 microg epinephrine (1:200,000) i.v., or 3 ml normal saline (n = 20 each). The HR and SBP were monitored for four minutes after injection of the study drug. RESULTS: Intravenous injection of the test dose produced HR increases > or = 20 beats x min(-1) in 18 (90%), 16 (80%) and 14 (70%) patients at sevoflurane concentrations at 0.5, 1 and 2%, respectively, while those receiving saline developed no HR changes. Based on the modified HR criterion, sensitivity, specificity, and positive and negative predictive values were all 100% under sevoflurane concentrations of 0.5 and 1%, but not 2%. On the other hand, all patients in the test dose groups and none in the saline groups developed SBP > or = 15 mmHg, ensuring 100% efficacy based on the conventional SBP criterion under all sevoflurane concentrations studied. In all patients receiving the intravenous test dose, peak HR occurred 30-45 sec earlier than that of SBP. CONCLUSION: During stable sevoflurane anesthesia, peak HR increase > or = 10 beats x min(-1) should be regarded as a positive response with end-tidal sevoflurane concentration < or = 1%, and peak SBP increase > or = 15 mmHg is applicable at sevoflurane concentrations between 0.5 and 2%.
This article has been cited by other articles:
![]() |
J. Guay The epidural test dose: a review. Anesth. Analg., March 1, 2006; 102(3): 921 - 929. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. A. Mowafi The Efficacy of Plethysmographic Pulse Wave Amplitude as an Indicator for Intravascular Injection of Epinephrine-Containing Epidural Test Dose in Anesthetized Adults Anesth. Analg., November 1, 2005; 101(5): 1506 - 1511. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. A. Mowafi Digital Skin Blood Flow as an Indicator for Intravascular Injection of Epinephrine-Containing Simulated Epidural Test Dose in Sevoflurane-Anesthetized Adults Anesth. Analg., August 1, 2005; 101(2): 584 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tanaka, T. Goyagi, T. Kimura, and T. Nishikawa The Efficacy of Hemodynamic and T wave Criteria for Detecting Intravascular Injection of Epinephrine Test Doses in Anesthetized Adults: A Dose-Response Study Anesth. Analg., October 1, 2000; 91(5): 1196 - 1202. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tanaka and T. Nishikawa Aging Reduces the Efficacy of the Simulated Epidural Test Dose in Anesthetized Adults Anesth. Analg., September 1, 2000; 91(3): 657 - 661. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |