CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Belani, K. G.
Right arrow Articles by Poliac, M. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Belani, K. G.
Right arrow Articles by Poliac, M. O.

Canadian Journal of Anesthesia, Vol 46, 488-496, Copyright © 1999 by Canadian Anesthesiologists' Society


ARTICLES

Accuracy of radial artery blood pressure determination with the Vasotrac

KG Belani, JJ Buckley and MO Poliac
Department of Anesthesiology, University of Minnesota Medical School, Minneapolis 55455, USA. belan001@tc.umn.edu

PURPOSE: To evaluate the accuracy of a new non-invasive method (Vasotrac) to measure blood pressure (BP) with accompanying arterial wave-form and pulse-rate display when compared with BP and waveform measured invasively. METHODS: Healthy volunteers (n=53) served as subjects for the study. Blood pressures and waveforms obtained via a radial artery catheter (IABP) were compared with non-invasive measurements obtained every 12-15 beats by the new system (Vasotrac BP) from the opposite radial artery. In a sub-group of volunteers (n=11), BP was acutely increased and decreased with isoproterenol, phenylephrine and sodium nitroprusside. Data were analyzed by determining correlation and agreement between the two systems of measurement. Waveforms obtained by the two systems were qualitatively examined. RESULTS: Non-invasive BP measured every 12-15 beats by the Vasotrac correlated with IABP (systolic r2 = 0.89; diastolic r2 = 0.88; mean r2 = 0.94). The actual values obtained by the two methods agreed closely with > 90% of readings being within 2SDs when plotted by the Bland Altman method. This was also true during vasoactive drug infusion when BP changed acutely and swiftly. During this dynamic period, Vasotrac BP accurately tracked the changes in IABP with correlations (systolic r2 = 0.82; diastolic r2 = 0.89; mean r2 = 0.95) and close agreement (> 90% of readings were within 2 SDs in the Bland Altman plot). Waveforms displayed by the two systems were qualitatively very similar. Pulse rates measured by the two systems were identical. CONCLUSIONS: The Vasotrac system displayed an arterial waveform which was similar to that obtained directly and measured BP and pulse rate accurately. It should be a convenient device to measure BP continually in a non-invasive fashion.


This article has been cited by other articles:


Home page
Psychosom. Med.Home page
P. H. Wirtz, S. Elsenbruch, L. Emini, K. Rudisuli, S. Groessbauer, and U. Ehlert
Perfectionism and the Cortisol Response to Psychosocial Stress in Men
Psychosom Med, April 1, 2007; 69(3): 249 - 255.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
P. H. Wirtz, R. von Kanel, C. Mohiyeddini, L. Emini, K. Ruedisueli, S. Groessbauer, and U. Ehlert
Low Social Support and Poor Emotional Regulation Are Associated with Increased Stress Hormone Reactivity to Mental Stress in Systemic Hypertension
J. Clin. Endocrinol. Metab., October 1, 2006; 91(10): 3857 - 3865.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Y. Findlay, B. Gali, M. T. Keegan, C. M. Burkle, and D. J. Plevak
Vasotrac(R) arterial blood pressure and direct arterial blood pressure monitoring during liver transplantation.
Anesth. Analg., March 1, 2006; 102(3): 690 - 693.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. E. McCann, D. Hill, K. C. Thomas, D. Zurakowski, and P. C. Laussen
A Comparison of Radial Artery Blood Pressure Determination Between the Vasotrac Device and Invasive Arterial Blood Pressure Monitoring in Adolescents Undergoing Scoliosis Surgery
Anesth. Analg., October 1, 2005; 101(4): 978 - 985.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. L. Cua, K. Thomas, D. Zurakowski, and P. C. Laussen
A Comparison of the Vasotrac with Invasive Arterial Blood Pressure Monitoring in Children After Pediatric Cardiac Surgery
Anesth. Analg., May 1, 2005; 100(5): 1289 - 1294.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the Canadian Anesthesiologists' Society.