CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brimacombe, J.
Right arrow Articles by Keller, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brimacombe, J.
Right arrow Articles by Keller, C.

Canadian Journal of Anesthesia, Vol 46, 558-563, Copyright © 1999 by Canadian Anesthesiologists' Society


ARTICLES

Comparison of the flexible and standard laryngeal mask airways

J Brimacombe and C Keller
Department of Anaesthesia and Intensive Care, Cairns Base Hospital, The Esplanade, Australia. 100236,2343@compuserve.com

PURPOSE: To determine mucosal pressures, ease of insertion, mask position and oropharyngeal leak pressures for the flexible (FLMA) and standard laryngeal mask airway (LMA). METHODS: Forty anesthetized, paralysed adult patients were randomly allocated to receive either the FLMA or LMA. Microchip sensors were attached to the LMA or FLMA at identical locations corresponding to the base of tongue, hypopharynx, lateral pharynx, oropharynx, posterior pharynx and pyriform fossa. Mucosal pressure, oropharyngeal leak pressure (OLP) and mask position (assessed fibreoptically) were recorded during inflation of the cuff from 0-40 ml in 10 ml increments. RESULTS: Ease of insertion and mask position were similar between devices. Mean OLP was higher for the LMA (22 vs 19 cm H2O), but the maximum OLP was similar (25 vs 24 cm H2O). Mean mucosal pressures were generally low (< 12 cm H2O) for both devices, but were higher for the LMA in the lateral pharynx (4 vs 1 cm H2O) and oropharynx (13 vs 3 cm H2O) and higher in the posterior pharynx for the FLMA (4 vs 2 cm H2O). The OLP for both devices increased with increasing intracuff volume from 0-10 ml and 10-20 ml, and from 20-30 ml for the FLMA. CONCLUSIONS: We conclude that the LMA and FLMA perform similarly in terms of ease of insertion and mask position, but OLP and mucosal pressures are slightly higher for the LMA. Pharyngeal mucosal pressures for both devices are lower than those considered safe for the tracheal mucosa. The overall clinical performance between the two devices is similar.