CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MacQuarrie, K.
Right arrow Articles by Law, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MacQuarrie, K.
Right arrow Articles by Law, J. A.

Canadian Journal of Anesthesia, Vol 46, 760-765, Copyright © 1999 by Canadian Anesthesiologists' Society


ARTICLES

Tracheal intubation using Bullard laryngoscope for patients with a simulated difficult airway

K MacQuarrie, OR Hung and JA Law
Department of Anesthesia, Dalhousie University, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada. kmacquar@is2.dal.ca

PURPOSE: To evaluate the utility and safety of orotracheal intubation in adult patients with simulated difficult airways using the Bullard Laryngoscope (BL). METHODS: A rigid cervical collar was used to simulate the difficult airway. The study consisted of two phases. Phase I evaluated the BL used in conjunction with an independently styletted endotracheal tube (ISETT) passed freehand into the trachea. Phase II evaluated the new Multifunctional Intubating Stylet (MFIS). Forty patients were studied in each phase. Following induction of anesthesia a rigid cervical collar was applied and the laryngoscopic grade assessed. Tracheal intubation was then performed using the BL with either an ISETT or the MFIS. The total time to intubate, number of attempts, failures, hemodynamic changes during intubation were recorded. RESULTS: The rigid collar effectively simulated a difficult laryngoscopy, 65% of patients had a grade 3 view. The success rates for tracheal intubation using the ISETT and MFIS were 88% and 83% respectively. The average times to intubation were similar for both intubating techniques (45.4 +/- 26.8 sec for the ISETT and 41.2 +/- 25.2 sec for the MFIS). Although there were minor hemodynamic changes, mucosal bleeding and sore throat following intubation, there were no major complications in any of the study patients. CONCLUSIONS: The BL, used with either an ISETT or the MFIS, is an effective and safe intubating device for patients with simulated restricted cervical spine movement. Further studies are needed to compare the effectiveness and safety of these two techniques in managing patients with a difficult airway.


This article has been cited by other articles:


Home page
ChestHome page
J. M. Walz, M. Zayaruzny, and S. O. Heard
Airway Management in Critical Illness
Chest, February 1, 2007; 131(2): 608 - 620.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
C. M. Goutcher and V. Lochhead
Reduction in mouth opening with semi-rigid cervical collars
Br. J. Anaesth., September 1, 2005; 95(3): 344 - 348.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
S. Kihara, Y. Yaguchi, N. Taguchi, J. R. Brimacombe, and S. Watanabe
The StyletScopeTM is a better intubation tool than a conventional stylet during simulated cervical spine immobilization: [Le StyletScopeTM est un meilleur outil d'intubation que le stylet traditionnel pendant l'immobilisation simulee de la colonne cervicale]
Can J Anesth, January 1, 2005; 52(1): 105 - 110.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
O. Hung and M. Murphy
Changing practice in airway management: are we there yet?/Evolution dans le controle des voies aeriennes : y sommes-nous deja ?
Can J Anesth, December 1, 2004; 51(10): 963 - 968.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
R. Komatsu, O. Nagata, K. Kamata, K. Yamagata, D. I. Sessler, and M. Ozaki
Intubating laryngeal mask airway allows tracheal intubation when the cervical spine is immobilized by a rigid collar
Br. J. Anaesth., November 1, 2004; 93(5): 655 - 659.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
O. Hung
Airway management: the good, the bad, and the ugly/Le controle des voies aeriennes : du meilleur au pire
Can J Anesth, October 1, 2002; 49(8): 767 - 771.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
E. Crosby
Modelling the difficult airway - how real is faking it?/La simulation de l'intubation difficile - jusqu'ou s'approche-t-on de la realite ?
Can J Anesth, May 1, 2002; 49(5): 448 - 452.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
R. B.P. Stasiuk
Improving styletted oral tracheal intubation: rational use of the OTSU : [L'amelioration de l'intubation oro-tracheale : l'utilisation rationnelle du SIOT]
Can J Anesth, October 1, 2001; 48(9): 911 - 918.
[Abstract] [Full Text] [PDF]


Home page
JWatch Emergency Med.Home page
Bullard Laryngoscopy with a Semi-Rigid Collar
Journal Watch Emergency Medicine, November 1, 1999; 1999(1101): 17 - 17.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the Canadian Anesthesiologists' Society.