CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weiss, M.
Right arrow Articles by Gerber, A. Ch.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weiss, M.
Right arrow Articles by Gerber, A. Ch.
Related Collections
Right arrow Cardiothoracic Anesthesia, Respiration and Airway
Canadian Journal of Anesthesia 47:280-284 (2000)
© Canadian Anesthesiologists' Society, 2000

Equipment

Difficult airway management: comparison of the Bullard laryngoscope with the video-optical intubation stylet

Markus Weiss, MD, Uwe Schwarz, MD and Andreas Ch. Gerber, MD

From the Department of Anaesthesia, University Children's Hospital, Steinwiesstrasse 75, Zurich, Switzerland.

Address correspondence to: Dr. Markus Weiss. Phone: +41-1-266-71-11; Fax: +41-1-266-71-68; E-Mail: markus.weiss{at}kispi.unizh.ch

Purpose: To evaluate, whether the video-optical intubation stylet (VOIS) was more successful for difficult tracheal intubation than the Bullard laryngoscope (BL).

Methods: An intubation mannequin head was modified so that, using a Macintosh blade size 3, only the epiglottis was visible at direct laryngoscopy, representing a grade III laryngoscopic view. Forty anesthesiologists attempted tracheal intubation using each technique. Tracheal intubation with the Bullard laryngoscope was performed using the attached non-malleable intubating stylet preloaded with an endotracheal tube. The video-optical intubation stylet inserted into an endotracheal tube was used with direct laryngoscopy. During conventional laryngoscopy, the video-view from the stylet tip allowed the tracheal tube to be guided behind the epiglottis into the trachea.

Ten attempts with each technique were performed by each anesthesiologist in randomized order. Intubation time, and failed intubation (> 60 sec / esophageal intubation) were recorded. The operators assessed the degree of difficulty of each method using a Likert-scale.

Results: Mean intubation time (19.2 ± 4.5 sec for the BL and 18.8 ± 4.6 sec for the VOIS) was almost the identical. The video-optical intubation stylet was associated with fewer failed intubations (8 vs 41; P < 0.005) and had a lower degree of difficulty (1.7 ± 0.65 for the VOIS and 2.6 ± 0.74 for the BL; P < 0.0001). No correlation was found between the anesthesiologist's experience and mean intubation time, estimated degree of difficulty or number of unsuccessful intubation.

Conclusion: The video-optical intubation stylet was a more effective and simpler intubation device to facilitate difficult tracheal intubation than the Bullard laryngoscope.




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
O. Hung and J. A. Law
Advances in airway management
Can J Anesth, June 1, 2006; 53(6): 628 - 631.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
E. B. Liem, D. G. Bjoraker, and D. Gravenstein
New options for airway management: intubating fibreoptic stylets{dagger}
Br. J. Anaesth., September 1, 2003; 91(3): 408 - 418.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
A. Dullenkopf, G. Lamesic, A. Gerber, and M. Weiss
Video-enhanced visualization of the larynx and intubation with the Bullard laryngoscope - equipment report: [La visualisation, facilitee par video, du larynx et de l'intubation avec le laryngoscope Bullard - une analyse de materiel]
Can J Anesth, May 1, 2003; 50(5): 507 - 510.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
R. B.P. Stasiuk
Improving styletted oral tracheal intubation: rational use of the OTSU : [L'amelioration de l'intubation oro-tracheale : l'utilisation rationnelle du SIOT]
Can J Anesth, October 1, 2001; 48(9): 911 - 918.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M. Weiss, K. Hartmann, J. Fischer, and A. C. Gerber
Video-intuboscopic assistance is a useful aid to tracheal intubation in pediatric patients : [L'assistance videoscopique facilite l'intubation endotracheale des patients pediatriques]
Can J Anesth, July 1, 2001; 48(7): 691 - 696.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M Weiss, U Schwarz, C. Dillier, and A. Gerber
Video-intuboscopic monitoring of tracheal intubation in pediatric patients
Can J Anesth, December 1, 2000; 47(12): 1202 - 1206.
[Abstract]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the Canadian Anesthesiologists' Society.