CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orser, B. A.
Right arrow Articles by Yee, D. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Orser, B. A.
Right arrow Articles by Yee, D. A.
Canadian Journal of Anesthesia 48:139-146 (2001)
© Canadian Anesthesiologists' Society, 2001

General Anesthesia

Medication errors in anesthetic practice: a survey of 687 practitioners

Beverley A. Orser, PhD MD FRCPC, Robert J.B. Chen, BSc MD FRCPC and Doreen A. Yee, MD FRCPC

From the Department of Anesthesia, Sunnybrook and Women's College Health Science Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario, M4N 3M5 Canada.

Address correspondence to: Dr. B. Orser. Phone: 416-978-0574; Fax: 416-978-4940; E-mail: beverley.orser{at}utoronto.ca

Purpose: The objectives of this study were to determine: 1) if anesthesiologists had experienced a medication error and 2) to identify causal factors. The perceived value of a Canadian reporting agency for medication errors and improved standards for labels on drug ampoules was also investigated.

Methods: A self-reporting survey was mailed to members of the Canadian Anesthesiologists' Society (n = 2,266). Respondents provided free-text descriptions of medication errors and answered fixed response questions.

Results: Surveys from 687 anesthesiologists (30% response rate) revealed that 85% of the participants had experienced at least one drug error or "near miss". Although most errors (1,038) were of minor consequence (98%), four deaths were reported. The commonest error involved the administration of muscle relaxants instead of a reversal agent. "Syringe swaps" (70.4%) and the misidentification of the label (46.8%) were common contributing factors. Anesthesiologists (97.9%) reported that they read the ampoule label "most of the time" although the label colour was an important secondary cue. Approximately half of the participants would report the error if a reporting program existed and 84% agreed that improved standards for drug labels would reduce the incidence of error.

Conclusions: Most anesthesiologists experienced at least one drug error. The commonest error was a "syringe swap" that involved a muscle relaxant. Most errors were of minor consequence, however, serious morbidity and mortality resulted from clearly preventable events. These results support the development of improved standards for drug labels and the establishment of a Canadian reporting program for medication errors.




This article has been cited by other articles:


Home page
SURG INNOVHome page
Yan Xiao, S. Schimpff, C. Mackenzie, R. Merrell, E. Entin, R. Voigt, and B. Jarrell
Video Technology to Advance Safety in the Operating Room and Perioperative Environment
Surgical Innovation, March 1, 2007; 14(1): 52 - 61.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
S. K. W. Schwarz
Can items on an aviation-style checklist for preparation of cesarean delivery under general anesthesia present a threat for patient safety?
Anesth. Analg., March 1, 2006; 102(3): 970 - 970.
[Full Text] [PDF]


Home page
CMAJHome page
B. A. Orser, C. Dionee, and S. Hyland
Drug safety in Canada: 2 steps forward, 1 step back
Can. Med. Assoc. J., January 3, 2006; 174(1): 66 - 66.
[Full Text] [PDF]


Home page
CMAJHome page
K. Feltmate
Drug safety in Canada: 2 steps forward, 1 step back
Can. Med. Assoc. J., January 3, 2006; 174(1): 66 - 67.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P. Dodek
Improving patient safety in critical care: big challenge, exciting opportunity/L'amelioration de la securite des patients a l'unite des soins intensifs : un grand defi, une occasion stimulante
Can J Anesth, May 1, 2005; 52(5): 459 - 462.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
D. A.E. Shephard
The changing pattern of anesthesia, 1954-2004: a review based on the content of the Canadian Journal of Anesthesia in its first half-century: [La transformation du modele de l'anesthesie, 1954-2004 : une revue fondee sur le contenu du premier demi-siecle du Journal canadien d'anesthesie]
Can J Anesth, March 1, 2005; 52(3): 238 - 248.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
B. A. Orser and R. Byrick
Anesthesia-related medication error: time to take action/Les erreurs de medication reliees a l'anesthesie : il est temps d'agir
Can J Anesth, October 1, 2004; 51(8): 756 - 760.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
D. Strock, K. M. Kuczkowski, and M. Greenberg
Accidental administration of succinylcholine for the treatment of hypotension in a labouring parturient
Can J Anesth, October 1, 2004; 51(8): 853 - 854.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
J.P. Jayasuriya and B. A. Orser
Medication safety in anesthetic practice
Can J Anesth, June 1, 2001; 48(6): 614 - 614.
[Full Text]