CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shaaban Ali, M.
Right arrow Articles by Latto, I.P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shaaban Ali, M.
Right arrow Articles by Latto, I.P.
Canadian Journal of Anesthesia 48:497-501 (2001)
© Canadian Anesthesiologists' Society, 2001

Cardiothoracic Anesthesia, Respiration and Airway

Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery

M. Shaaban Ali, MB BCH MSc, M. Harmer, MD FRCA, R.S. Vaughan, FRCA, J.A. Dunne, FRCA and I.P. Latto, FRCA

From the Department of Anaesthetics and Intensive Care Medicine, University of Wales College of Medicine, Heath Hospital, Heath Park, Cardiff, UK.

Address correspondence to: Dr. M. Shaaban Ali, Department of Anaesthesia, University of Wales College of Medicine, Cardiff CF14 4XN, UK. Phone: 0044-29-20-743110; Fax: 0044-29-20-747203; E mail: msali58{at}hotmail.com

Purpose: Near infrared spectroscopy (NIRS) is a promising non-invasive method for continuous monitoring of cerebral oxygenation during cardiac surgery with cardiopulmonary bypass (CPB). This study was designed to study the agreement between tissue oxygen index (TOI) measured by spatially resolved spectroscopy (NIRO-300) and jugular bulb oxygen saturation (SjO2) in patients undergoing warm coronary bypass surgery.

Methods: Seventeen patients undergoing warm coronary artery bypass surgery were studied. NIRS was continuously monitored and was averaged before CPB, five, 20, 40, 60 min on CPB, five minutes before end of CPB and ten minutes after CPB to coincide with SjO2 measurements. Bypass temperature was maintained at 34–37°C.

Results: Bland and Altman analysis showed a bias (TOI–SjO2) of -6.7%, and wide limits of agreement (from 16% to -28%) between the two methods. In addition, mean TOI was lower than mean SjO2 during and after CPB. We observed a statistically significant correlation between arterial carbon dioxide and SjO2 measurements (r2=0.33; P=0.0003), but the former did not correlate with TOI values (r2=0.001; P=0.7).

Conclusion: Our results demonstrate a lack of agreement between SjO2 and TOI for monitoring cerebral oxygenation during cardiac surgery. We conclude that the two methods are not interchangeable.




This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. Chakravarti, S. Srivastava, and A. J. C. Mittnacht
Near Infrared Spectroscopy (NIRS) in Children
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2008; 12(1): 70 - 79.
[Abstract] [PDF]


Home page
StrokeHome page
P. G. Al-Rawi and P. J. Kirkpatrick
Tissue Oxygen Index: Thresholds for Cerebral Ischemia Using Near-Infrared Spectroscopy
Stroke, November 1, 2006; 37(11): 2720 - 2725.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
T. M. Hemmerling, J.-F. Olivier, F. Basile, N. Le, and I. Prieto
Bispectral Index as an Indicator of Cerebral Hypoperfusion During Off-Pump Coronary Artery Bypass Grafting
Anesth. Analg., February 1, 2005; 100(2): 354 - 356.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M.-C. Taillefer and A. Y. Denault
Cerebral near-infrared spectroscopy in adult heart surgery: systematic review of its clinical efficacy: [La spectroscopie cerebrale par infrarouge en cardiochirurgie chez l'adulte : une etude systematique de son efficacite clinique]
Can J Anesth, January 1, 2005; 52(1): 79 - 87.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
N. Nagdyman, T. P. K. Fleck, P. Ewert, H. Abdul-Khaliq, M. Redlin, and P. E. Lange
Cerebral oxygenation measured by near-infrared spectroscopy during circulatory arrest and cardiopulmonary resuscitation
Br. J. Anaesth., September 1, 2003; 91(3): 438 - 442.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
G Naulaers, G Morren, S Van Huffel, P Casaer, and H Devlieger
Cerebral tissue oxygenation index in very premature infants
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2002; 87(3): F189 - 192.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
M. Weiss, G. Schulz, M. Fasnacht, C. Balmer, J. E. Fischer, A. C. Gerber, H.-U. Bucher, and O. Baenziger
Transcutaneously measured near-infrared spectroscopic liver tissue oxygenation does not correlate with hepatic venous oxygenation in children: [La mesure transcutanee de l'oxygenation du tissu hepatique par spectroscopie proche infrarouge ne correspond pas a l'oxygenation hepatique veineuse chez les enfants]
Can J Anesth, October 1, 2002; 49(8): 824 - 829.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the Canadian Anesthesiologists' Society.