CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bissonnette, B.
Right arrow Articles by Paut, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bissonnette, B.
Right arrow Articles by Paut, O.
Canadian Journal of Anesthesia 49:270-275 (2002)
© Canadian Anesthesiologists' Society, 2002

Obstetrical and Pediatric Anesthesia

Active warming of saline or blood is ineffective when standard infusion tubing is used: an experimental study

[Le réchauffement actif d'une solution salée ou de sang est inefficace quand on utilise une tubulure à perfusion standard]

Bruno Bissonnette, MD FRCPC and Olivier Paut, MD

From the Department of Anaesthesia, The Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada.

Dr. Bruno Bissonnette, Department of Anaesthesia, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G 1X8, Canada. Phone: 416-813-7455; Fax: 416-813-7543; E-mail: bruno{at}anaes.sickkids.on.ca

Purpose: To determine the effect of infusion rate, tubing length and fluid composition on the temperature of the infusate reaching the distal end of an infusion tubing with and without active fluid warming.

Methods: Warmed normal saline (W-NS) and packed red blood cells (W-PRBC), were infused with a fluid warmer through a modified infusion set. The fluids were delivered at eight infusion rates from 50 to 999 mL•hr-1. The infusate temperature was monitored at 20 cm intervals on the iv tubing. The same temperature monitoring protocol was applied to PRBC without warmer (NoW-PRBC).

Results: In W-NS and W-PRBC groups, there was a decrease in the infusate temperature, at each flow rate, from the drip chamber to the distal end of tubing ( P <0.001). In NoW-PRBC group, there was a rapid increase in the infusate temperature from the bag to the drip chamber ( P <0.001). Thereafter, there was no change in temperature, except at the 999 mL•hr-1 infusion rate, where a slight increase in the infusate temperature throughout the tubing was shown. In W-NS and W-PRBC groups increasing the flow rate produced a significant increase in the infusate temperature, at each measurement point ( P <0.001). In the NoW-PRBC group, increasing the flow rate did not alter the infusate temperature. The fluid composition did not influence the infusate temperature.

Conclusion: There is an important heat exchange within the tubing, which is aggravated at low flow rates. At infusion rates appropriate for pediatric anesthesia the clinical and economic value of fluid warming without the use of heated extension tubing is questionable.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
A. Wadhwa, R. Komatsu, M. Orhan-Sungur, P. Barnes, J. In, D. I. Sessler, and R. Lenhardt
New Circulating-Water Devices Warm More Quickly than Forced-Air in Volunteers
Anesth. Analg., December 1, 2007; 105(6): 1681 - 1687.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. E. Horowitz, M. A. Delagarza, J. J. Pulaski, and R. A. Smith
Flow Rates and Warming Efficacy with Hotline and Ranger Blood/Fluid Warmers
Anesth. Analg., September 1, 2004; 99(3): 788 - 792.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the Canadian Anesthesiologists' Society.