| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |


* From the Departments of Anaesthesia and Intensive Care Medicine,
Hygiene and Social Medicine, and
Pathology, University of Innsbruck, Innsbruck, Austria.
Dr. Christian Kolbitsch, Department of Anaesthesia and Intensive Care Medicine, University of Innsbruck, Anichstr. 35, A-6020 Innsbruck, Austria. Phone: +43-(0) 512-504-2400; Fax: +43-(0) 512-504-2450; E-mail: christian.kolbitsch{at}uibk.ac.at
Purpose: Propofol is a potential vector of infection, because it contains no preservative. Thus, the manufacturer's specific recommendations for preparing injections or infusions go beyond the guidelines commonly used in our operating rooms for preparing other iv drugs. The purpose of the present study was to determine whether in the daily routine of an operating theatre a modified propofol handling technique can prevent contamination as effectively as do the manufacturer's handling recommendations.
Methods: A total of 160 consecutive neurosurgical patients were allocated to either Group I (manufacturer's handling recommendations: i.e., 1) disinfecting propofol vials and ampoules before filling syringes; 2) replacing empty syringes; 3) discarding all material at the end of surgery); or Group II (modified propofol handling protocol: i.e., 1) refilling empty syringes; 2) renewing only the infusion line to the patient).
Results: Total contamination rates were comparable in both groups (Group I: 14/160 (8.75%), Group II: 13/160 (8.13%) (
2P=0.96). Frequency of contamination was not different between groups; either in sample 1 taken at the beginning of the procedure, (Group I: 5/80 (6.25%) vs Group II: 6/80 (7.5%);
2=0.098; P=0.76) or in sample 2, taken at the end, (Group I: 9/80 (11.25%) vs Group II: 7/80 (8.75%);
2=0.278; P=0.598).
Conclusion: We conclude that in the daily routine of the operating theatre following a modified propofol handling protocol prevents contamination of propofol syringes as effectively as does adhering to the manufacturer's specific handling recommendations. However, neither of the tested guidelines completely prevented contamination.
This article has been cited by other articles:
![]() |
B. B. Abdelmalak, C. A. Bashour, and J. P. Yared Skin infection and necrosis after subcutaneous infiltration of propofol in the intensive care unit Can J Anesth, July 1, 2008; 55(7): 471 - 473. [Full Text] [PDF] |
||||
![]() |
C. A. Trepanier and M. R. Lessard Propofol and the risk of transmission of infection/Le propofol et le risque de transmission d'infection Can J Anesth, June 1, 2003; 50(6): 533 - 537. [Full Text] [PDF] |
||||
![]() |
W. C. E. Hall, D. T. Jolly, J. Hrazdil, J. C. Galbraith, M. Greacen, and A. S. Clanachan The EmulSivTM filter removes microbial contamination from propofol but is not a substitute for aseptic technique: [Le filtre EmulSivTM elimine la contamination microbienne du propofol, mais ne remplace pas l'asepsie] Can J Anesth, June 1, 2003; 50(6): 541 - 546. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Sosis On the proper sterile technique for handling of propofol Can J Anesth, November 1, 2002; 49(9): 1000 - 1000. [Full Text] [PDF] |
||||
![]() |
T. Hackmann, C. S. Soder, and C. Kolbitsch Preventing contamination of propofol infusions Can J Anesth, October 1, 2002; 49(8): 886 - 886. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |