| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
ur battant]

* From the Departments of Anesthesiology, and
Surgery Montreal Heart Institute, Montreal, Quebec, Canada.
Dr. Pierre Couture, Department of Anesthesiology, Montreal Heart Institute, 5000 Bélanger Street East, Montreal, Quebec H1T 1C8, Canada. Phone: 514-376-3330, ext. 3732; Fax: 514-376-1355; E-mail: p.couture{at}sympatico.ca
Purpose: To describe the mechanisms of hemodynamic changes during off-pump coronary artery bypass graft surgery (OP-CABG).
Source: Pertinent medical literature in the English and French languages was identified through a Medline computerized literature search and a manual search of selected articles, using off-pump coronary artery surgery, beating heart surgery, hemodynamic, and transesophageal echocardiography as key words. Human and animal studies were included.
Principal finding: Hemodynamic variations in OP-CABG may be due to mobilization and stabilization of the heart, or myocardial ischemia occurring during coronary occlusion. Suction type and compression type stabilizers produce hemodynamic effects through different mechanisms. Heart dislocation (90° anterior displacement) and compression of the right ventricle to a greater extent than the left ventricle are responsible for hemodynamic alterations when using suction type stabilizers. Compression of the left ventricular outflow tract and abnormal diastolic expansion secondary to direct deformation of the left ventricular geometry are proposed mechanisms for hemodynamic derangements with compression type stabilizer. Coronary occlusion during the anastomosis can have additional effects on left ventricular function, depending on the status of collateral flow. The value and limitations of electrocardiographic (ECG), hemodynamic and echocardiographic monitoring modalities during OP-CABG are reviewed.
Conclusions: In summary, hemodynamic changes which can either be secondary to the stabilization technique or to transient ischemia represent an important diagnostic challenge during off-bypass procedures. The mechanism can vary according to the stabilization system. Current monitoring such as ECG and hemodynamic monitoring are used but remain limited in establishing the cause of hemodynamic instability. Transesophageal echocardiography is used in selected patients to diagnose the etiology of hemodynamic instability and can direct therapy, particularly in those with severe myocardial systolic and diastolic dysfunction, mild to moderate mitral regurgitation, or for patients who are unstable during the procedure.
This article has been cited by other articles:
![]() |
S. Rex, S. Brose, S. Metzelder, L. de Rossi, S. Schroth, R. Autschbach, R. Rossaint, and W. Buhre Normothermic Beating Heart Surgery with Assistance of Miniaturized Bypass Systems: The Effects on Intraoperative Hemodynamics and Inflammatory Response Anesth. Analg., February 1, 2006; 102(2): 352 - 362. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Collins, F. Girard, D. Boudreault, P. Chouinard, L. Normandin, P. Couture, M.-J. Caron, and M. Ruel Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output: [Le Doppler oesophagien et la thermodilution ne sont pas interchangeables pour preciser le debit cardiaque] Can J Anesth, November 1, 2005; 52(9): 978 - 985. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Omae, Y. Kakihana, A. Mastunaga, I. Tsuneyoshi, K. Kawasaki, Y. Kanmura, and R. Sakata Hemodynamic Changes During Off-Pump Coronary Artery Bypass Anastomosis in Patients with Coexisting Mitral Regurgitation: Improvement with Milrinone Anesth. Analg., July 1, 2005; 101(1): 2 - 8. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Tonkovic, I. Husedzinovic, S. Barisin, N. Bradic, S. Schmidt, and A. Barisin Hemodynamic response to moderate dobutamine dose in OPCAB during acute normovolemic hemodilution Can J Anesth, February 1, 2005; 52(2): 214 - 215. [Full Text] [PDF] |
||||
![]() |
H. K. Shinn, Y. J. Oh, S. H. Kim, J. H. Lee, C. S. Lee, and Y. L. Kwak Evaluation of serial haemodynamic changes during coronary artery anastomoses in patients undergoing off-pump coronary artery bypass graft surgery: initial experiences using two deep pericardial stay sutures and octopus tissue stabilizer Eur. J. Cardiothorac. Surg., June 1, 2004; 25(6): 978 - 984. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.L. Kwak, Y.J. Oh, S.M. Jung, K.J. Yoo, J.H. Lee, and Y.W. Hong Change in right ventricular function during off-pump coronary artery bypass graft surgery Eur. J. Cardiothorac. Surg., April 1, 2004; 25(4): 572 - 577. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verma, P. W.M. Fedak, R. D. Weisel, P. E. Szmitko, M. V. Badiwala, D. Bonneau, D. Latter, L. Errett, and Y. LeClerc Off-Pump Coronary Artery Bypass Surgery: Fundamentals for the Clinical Cardiologist Circulation, March 16, 2004; 109(10): 1206 - 1211. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |