Purpose: To describe the clinical use of a new videolaryngoscope in a patient who had repeatedly been difficult or impossible to intubate by conventional direct laryngoscopy. This device provided excellent glottic visualization and permitted easy endotracheal intubation.
Clinical features: A 74-yr-old male presenting for repeat elective surgery had a history of failed intubations by direct laryngoscopy and pulmonary aspiration with a laryngeal mask airway. He refused awake flexible fibreoptic intubation. After the induction of general anesthesia, laryngoscopy was performed using a GlideScope®. This provided complete glottic exposure and easy endotracheal intubation.
Conclusion: This new videolaryngoscope provided excellent laryngeal exposure in a patient whom multiple experienced anesthesiologists had repeatedly found to be difficult or impossible to intubate using direct laryngoscopy. The clinical role of this device awaits confirmation in a large series of difficult airways.
This article has been cited by other articles:
![]() |
F. S. Xue, Q. Y. Yang, N. He, and Y. C. Xu The modified ventilating tube changer to facilitate tracheal intubation using the GlideScope(R) in patients with a limited mouth opening Br. J. Anaesth., July 1, 2008; 101(1): 126 - 127. [Full Text] [PDF] |
||||
![]() |
Y. Enomoto, T. Asai, T. Arai, K. Kamishima, and Y. Okuda Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study Br. J. Anaesth., April 1, 2008; 100(4): 544 - 548. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Robitaille, S. R. Williams, M.-H. Tremblay, F. Guilbert, M. Theriault, and P. Drolet Cervical Spine Motion During Tracheal Intubation with Manual In-Line Stabilization: Direct Laryngoscopy versus GlideScope(R) Videolaryngoscopy Anesth. Analg., March 1, 2008; 106(3): 935 - 941. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Belyamani, S. Zidouh, and N. D. Kamili Intubation chez une adolescente souffrant du syndrome Rubinstein-Taybi en utilisant le videolaryngoscope [Intubation using a videolaryngoscope in an adolescent girl with Rubinstein-Taybi syndrome] Can J Anesth, January 1, 2008; 55(1): 57 - 58. [Full Text] [PDF] |
||||
![]() |
B. Shippey, D. Ray, and D. McKeown Use of the McGrath(R) videolaryngoscope in the management of difficult and failed tracheal intubation Br. J. Anaesth., January 1, 2008; 100(1): 116 - 119. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Asai, Y. Enomoto, K. Shimizu, K. Shingu, and Y. Okuda The Pentax-AWS Video-Laryngoscope: The First Experience in One Hundred Patients Anesth. Analg., January 1, 2008; 106(1): 257 - 259. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cortellazzi, L. Minati, C. Falcone, M. Lamperti, and D. Caldiroli Predictive value of the El-Ganzouri multivariate risk index for difficult tracheal intubation: a comparison of Glidescope(R) videolaryngoscopy and conventional Macintosh laryngoscopy Br. J. Anaesth., December 1, 2007; 99(6): 906 - 911. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Prabhu, D. Wong, S. Chakraborty, E Massicotte, G Tan, and R Cooper 44518 - RADIOGRAPHIC EVALUATION OF CERVICAL SPINE MOVEMENT DURING FLEXIBLE VIDEOBRONCHOSCOPY & LO-PRO GLIDESCOPE; A RANDOMISED CONTROLLED TRIAL Can J Anesth, August 1, 2007; 54(suppl_1): 44518 - 44518. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Lane and G. Lewis Combined use of a videolaryngoscope and a transilluminating device for intubation Can J Anesth, July 1, 2007; 54(7): 589 - 590. [Full Text] [PDF] |
||||
![]() |
B. Shippey, D. Ray, and D. McKeown Case series: The McGrath(R) videolaryngoscope - an initial clinical evaluation: [Serie de cas : Le videolaryngoscope McGrath(R) - une premiere evaluation clinique] Can J Anesth, April 1, 2007; 54(4): 307 - 313. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Cooper Complications associated with the use of the GlideScope(R) videolaryngoscope: [Complications suite a l'utilisation du videolaryngoscope GlideScope(R)] Can J Anesth, January 1, 2007; 54(1): 54 - 57. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Muallem and A. Baraka Tracheal intubation using the GlideScope(R) with a combined curved pipe stylet, and endotracheal tube introducer Can J Anesth, January 1, 2007; 54(1): 77 - 78. [Full Text] [PDF] |
||||
![]() |
Y. Hirabayashi GlideScope(R) videolaryngoscope facilitates nasotracheal intubation. Can J Anesth, November 1, 2006; 53(11): 1163 - 1164. [Full Text] [PDF] |
||||
![]() |
S. Matsumoto, T. Asai, and K. Shingu Truview video laryngoscope in patients with difficult airways. Anesth. Analg., August 1, 2006; 103(2): 492 - 493. [Full Text] [PDF] |
||||
![]() |
O. Hung and J. A. Law Advances in airway management Can J Anesth, June 1, 2006; 53(6): 628 - 631. [Full Text] [PDF] |
||||
![]() |
E. Falco-Molmeneu, F. Ramirez-Montero, R. Carregui-Tuson, N. Santamaria-Arribas, T. Gallen-Jaime, and M. Vila-Sanchez The modified Eschmann guide to facilitate tracheal intubation using the GlideScope(R). Can J Anesth, June 1, 2006; 53(6): 633 - 634. [Full Text] [PDF] |
||||
![]() |
D. Trevisanuto, E. Fornaro, and C. Verghese The GlideScope(R) video laryngoscope: initial experience in five neonates. Can J Anesth, April 1, 2006; 53(4): 423 - 424. [Full Text] [PDF] |
||||
![]() |
T. P. Turkstra, R. A. Craen, D. M. Pelz, and A. W. Gelb Cervical Spine Motion: A Fluoroscopic Comparison During Intubation with Lighted Stylet, GlideScope, and Macintosh Laryngoscope Anesth. Analg., September 1, 2005; 101(3): 910 - 915. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Cook, G. Lee, and J. P. Nolan The ProSealTM laryngeal mask airway: a review of the literature: [Le masque larynge ProSealTM : un examen des publications] Can J Anesth, August 1, 2005; 52(7): 739 - 760. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Zura, D. J. Doyle, and M. Orlandi Use of the Aintree intubation catheter(R) in a patient with an unexpected difficult airway: [L'usage d'un Aintree intubation catheter(R) dans un cas d'intubation difficile imprevue] Can J Anesth, June 1, 2005; 52(6): 646 - 649. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Hernandez and D. H. Wong Using a Glidescope for intubation with a double lumen endotracheal tube Can J Anesth, June 1, 2005; 52(6): 658 - 659. [Full Text] [PDF] |
||||
![]() |
J. V. Cuchillo and M. A. Rodriguez Considerations aimed at facilitating the use of the new GlideScope(R) videolaryngoscope Can J Anesth, June 1, 2005; 52(6): 661 - 661. [Full Text] [PDF] |
||||
![]() |
D. A. Sun, C. B. Warriner, D. G. Parsons, R. Klein, H. S. Umedaly, and M. Moult The GlideScope(R) Video Laryngoscope: randomized clinical trial in 200 patients Br. J. Anaesth., March 1, 2005; 94(3): 381 - 384. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Cooper, J. A. Pacey, M. J. Bishop, and S. A. McCluskey Early clinical experience with a new videolaryngoscope (GlideScope(R)) in 728 patients: [Experience clinique preliminaire avec un nouveau videolaryngoscope (GlideScope(R)) chez 728 patients] Can J Anesth, February 1, 2005; 52(2): 191 - 198. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Asai Editorial II: Who is at increased risk of pulmonary aspiration? Br. J. Anaesth., October 1, 2004; 93(4): 497 - 500. [Full Text] [PDF] |
||||
![]() |
Y. Lim, T.-J. Lim, and E. H.C. Liu Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways Can J Anesth, June 1, 2004; 51(6): 641 - 642. [Full Text] |
||||
![]() |
D. J. Doyle Miniaturizing the GlideScope(R) video laryngoscope system: a new design for enhanced portability Can J Anesth, June 1, 2004; 51(6): 642 - 643. [Full Text] |
||||
![]() |
R. M. Cooper Laryngoscopy -- its past and future Can J Anesth, June 1, 2004; 51(suppl_1): R6 - R6. [Full Text] [PDF] |
||||
![]() |
D. J. Doyle Awake intubation using the GlideScope(R) video laryngoscope: initial experience in four cases Can J Anesth, May 1, 2004; 51(5): 520 - 521. [Full Text] |
||||
![]() |
M. B. Kaplan and G. Berci Videolaryngoscopy in the management of the difficult airway Can J Anesth, January 1, 2004; 51(1): 94 - 94. [Full Text] |
||||
![]() |
D. J. Doyle, A. Zura, and M. Ramachandran Videolaryngoscopy in the management of the difficult airway Can J Anesth, January 1, 2004; 51(1): 95 - 95. [Full Text] |
||||
![]() |
R. M. Cooper REPLY Can J Anesth, January 1, 2004; 51(1): 95 - 96. [Full Text] [PDF] |
||||
![]() |
R. M. Cooper REPLY Can J Anesth, November 1, 2003; 50(9): 966 - 966. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |