CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Iohom, G.
Right arrow Articles by Lyons, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Iohom, G.
Right arrow Articles by Lyons, B.
Canadian Journal of Anesthesia 51:155-159 (2004)
© Canadian Anesthesiologists' Society, 2004

Obstetrical and Pediatric Anesthesia

The McCoy straight blade does not improve laryngoscopy and intubation in normal infants

[La lame droite McCoy n’améliore pas la laryngoscopie ni l’intubation chez des enfants normaux]

Gabriella Iohom, FCARCSI, Robert Franklin, FCARCSI, William Casey, FCARCSI and Barry Lyons, FCARCSI

From the Department of Anaesthesia and Intensive Care, Our Lady’s Hospital for Sick Children, Dublin, Ireland.

Address correspondence to: Dr. G. Iohom, Department of Anaesthesia, Cork University Hospital, Cork, Ireland. Phone: +353-21-4922134; Fax: +353-21-4546434; E-mail: iohom{at}hotmail.com

Purpose: The McCoy curved blade laryngoscope has been demonstrated to improve view at laryngoscopy in adults. A straight-bladed version of this laryngoscope has recently been introduced into pediatric practice. The objective of this prospective, randomized study was to compare the intubating conditions afforded by the McCoy (#1) straight blade laryngoscope with the conventional Miller (#1) blade in neonates and infants.

Methods: Forty patients under six months of age, were randomized into two groups: one group (n = 20) had an initial laryngoscopy with the McCoy blade and then had a laryngoscopy and subsequent intubation using the Miller blade; the second group (n = 20) had an initial laryngoscopy with the Miller blade, followed by laryngoscopy and intubation using the McCoy blade. All intubations were performed by one anesthesiologist familiar with using both blades.

Results: The majority of patients (39 out of 40) had a similar or superior view (Cormack and Lehane classification) with the Miller when compared with the McCoy laryngoscope. Mean time to laryngoscopy was 14.9 (12.7) sec with the McCoy and 6.8 (2.07) sec with the Miller blade (P = 0.001), whereas mean time to intubation was 25.13 (10.4) sec with the McCoy and 12 (8.5) sec with the Miller blade (P = 0.014). There was no difference between the groups regarding desaturation and changes in heart rate during laryngoscopy and intubation.

Conclusion: Our data indicate that the McCoy blade has no advantage over the conventional pediatric Miller blade in normal infants.




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
E. McCoy
The McCoy laryngoscope in infants and children/L'usage du laryngoscope McCoy chez les enfants
Can J Anesth, February 1, 2004; 51(2): 101 - 105.
[Full Text] [PDF]