CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lena, P.
Right arrow Articles by Martin, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lena, P.
Right arrow Articles by Martin, R.
Canadian Journal of Anesthesia 52:618-621 (2005)
© Canadian Anesthesiologists' Society, 2005

Regional Anesthesia and Pain

Subdural placement of an epidural catheter detected by nerve stimulation

[Positionnement sous-dural d’un cathéter épidural détecté par stimulation nerveuse et confirmé par tomographie]

Pierre Lena, MD* and René Martin, MD FRCP{dagger}

* From the Department of Cardiologie médico-chirurgicale, Institut Arnault Tzanck, Saint Laurent du Var, France; and
{dagger} the Department of Anesthesiology, Université de Sherbrooke, Sherbrooke, Québec, Canada.

Address correspondence to: Dr. Pierre Lena, Cardiologie médico-chirurgicale, Institut Arnault Tzanck, Avenue du Docteur Maurice Donat, Saint Laurent du Var, France 06721. Phone: 33-92-27-55-13; Fax: 04-92-27-39-06; E-mail: Pierre.Lena{at}wanadoo.fr

Purpose: Subdural placement of an epidural catheter is rare and difficult to detect. Electrical stimulation of the epidural space can be useful to detect such an event. The purpose of the present case report is to confirm the efficacy of electrical stimulation to detect a subdural placement of an epidural catheter and to illustrate this unusual positioning by computed tomography (CT) scan images.

Clinical features: A 51-yr-old man was scheduled for an aorto-iliac bypass on a combined epidural and general anesthesia technique. Electrical epidural stimulation was used. A very low threshold of 0.3 mA was observed with diffuse response movement at T3 and at T10, without cerebrospinal fluid return on catheter aspiration. An injection of 12 mL of 2% lidocaine with epinephrine 1/200,000 produced signs of iv injection of local anesthetic and an extensive block. Subdural placement of the catheter, suspected by the low current threshold response to epidural catheter stimulation, was confirmed by CT scan imaging.

Conclusion: The present case report confirms that electrical stimulation of the epidural space is useful to detect misplacement of epidural catheter such as a subdural placement. CT scan imaging of subdural positioning of an epidural catheter is presented.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. Guay
The epidural test dose: a review.
Anesth. Analg., March 1, 2006; 102(3): 921 - 929.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS