CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ruettimann, U.
Right arrow Articles by Pargger, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ruettimann, U.
Right arrow Articles by Pargger, H.
Canadian Journal of Anesthesia 53:101-105 (2006)
© Canadian Anesthesiologists' Society, 2006

Neuroanesthesia and Intensive Care

Management of acute respiratory distress syndrome using pumpless extracorporeal lung assist

[Traitement du syndrome de détresse respiratoire aiguë avec assistance respiratoire extracorporelle sans pompe]

Urban Ruettimann, md*, Wolfgang Ummenhofer, md*, Florian Rueter, md{dagger} and Hans Pargger, md*

* From the Division of Operative Critical Care, Department of Anesthesia; and
{dagger} the Division of Cardiothoracic Surgery, University Hospital Basel, Basel, Switzerland.

Address correspondence to: Dr. Wolfgang Ummenhofer, University Hospital Basel, Spitalstrasse 21, CH-4031 Basel, Switzerland. Phone: +41 61 265 25 25; Fax: +41 61 265 73 20; E-mail: wummenhofer{at}uhbs.ch

Purpose: To describe the use of a pumpless extracorporeal lung assist device in the treatment of severe acute respiratory distress syndrome (ARDS).

Clinical features: A 15-yr-old girl developed severe post-traumatic ARDS. After all conventional treatment strategies failed, we inserted a pumpless extracorporeal lung assist device. This device consists of an arterial cannula inserted into the femoral artery, and a membrane oxygenator with a venous cannula that returns the oxygenated blood back to the patient’s femoral vein. Since the driving force is the patient’s blood pressure, a roller pump with its negative side effects is not needed. The device allowed removal of excessive PaCO2 and, by applying minimal ventilation, minimization of further ventilator-induced lung injury. The pumpless extracorporeal lung assist device remained in situ for ten days without any adverse side effect. During this time, the lung recovered such that mechanical ventilation could be reinstalled cautiously. The device was then removed and, after a prolonged period of intensive care, the patient recovered without any sequelae.

Conclusion: In this case of a severely damaged lung, an arteriovenous pumpless extracorporeal lung assist was a helpful device to remove elevated CO2 and reduce mechanical stress by applying minimal ventilation. This device is simple to operate and has the potential of being used routinely in the treatment of severe ARDS.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
B. Florchinger, A. Philipp, A. Klose, M. Hilker, R. Kobuch, L. Rupprecht, A. Keyser, T. Puhler, S. Hirt, K. Wiebe, et al.
Pumpless extracorporeal lung assist: a 10-year institutional experience.
Ann. Thorac. Surg., August 1, 2008; 86(2): 410 - 417.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Canadian Anesthesiologists' Society.