| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
From the Department of Anaesthetics, Guys, Kings and St. Thomas School of Medicine, Kings College London, London, United Kingdom.
Address correspondence to: Dr. Donald M. Miller, GKT Department of Anaesthetics, 2nd Floor, NGH, Guys Hospital, London SE1 9RT, United Kingdom. Phone: +44 20 71880637; Fax: +44 20 71880642; E-mail: donald.miller{at}kcl.ac.uk
Purpose: To compare the efficacy of the ProSeal LMATM and SLIPATM supralaryngeal airways (SLA) with the standard tracheal tube (TT) in 150 consecutive day-case laparoscopic gynecological surgery procedures requiring general anesthesia.
Methods: One hundred and fifty patients were randomized into three groups. An identical general anesthesia technique was used in all patients apart from the addition of muscle relaxants and reversal drugs in the TT group. Patients were excluded if there were risk factors for gastroesophageal reflux. Ease of use, quality of seal, ventilation, systolic pressure, response to intubation, side effects and operating room time were assessed.
Results: Both ProSeal LMATM and SLIPATM were easy to insert (100% success) and ventilate with respective mean (standard deviation) maximum sealing pressures of 31 (4.6) and 30 (5.2) cmH2O (P = 0.4) with no muscle relaxants. The seal quality in both ProSeal LMATM and SLIPATM permitted the use of low flows, 485 (291) and 539 (344) mL·min1 (P = 0.2) respectively, although in the TT group significantly lower flows [377 (124) mL·min1], (P < 0.01) were achieved. Systolic pressure in the SLA groups was more stable in response to insertion than in the TT. With ProSealTM there was a lower incidence of sore throats than with TT (30% vs 57%), (P < 0.05), but there was a lesser difference as compared with SLIPATM (30% vs 49%), (P > 0.05). With both SLAs, there was a significant reduction in operating room time (> three minutes), (P < 0.001).
Conclusions: These results suggest that the ProSeal LMATM (reusable) and SLIPATM (single-use) SLAs were easy to use without requiring muscle relaxants, and reduce operating room time compared to the TT technique in day case laparoscopies.
This article has been cited by other articles:
![]() |
H. Hooshangi and D. T. Wong Brief Review: The Cobra Perilaryngeal Airway (CobraPLA(R)) and the Streamlined Liner of Pharyngeal Airway (SLIPATM) supraglottic airways: [Article de synthese court : Les dispositifs supraglottiques Cobra Perilaryngeal Airway (CobraPLA(R)) et Streamlined Liner of Pharyngeal Airway (SLIPATM)] Can J Anesth, March 1, 2008; 55(3): 177 - 185. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Miller Laryngeal Mask Airway Classic and Streamlined Pharynx Airway Liner Airway Comparison Anesth. Analg., November 1, 2007; 105(5): 1508 - 1508. [Full Text] [PDF] |
||||
![]() |
M. Lange, T. Smul, P. Zimmermann, R. Kohlenberger, N. Roewer, and F. Kehl The Effectiveness and Patient Comfort of the Novel Streamlined Pharynx Airway Liner (SLIPA(R)) Compared with the Conventional Laryngeal Mask Airway in Ophthalmic Surgery Anesth. Analg., February 1, 2007; 104(2): 431 - 434. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |