CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Résumé de cet Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shippey, B.
Right arrow Articles by McKeown, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shippey, B.
Right arrow Articles by McKeown, D.
Canadian Journal of Anesthesia 54:307-313 (2007)
© Canadian Anesthesiologists' Society, 2007

Case Reports/Case Series

Case series: The McGrath® videolaryngoscope - an initial clinical evaluation

[Série de cas : Le vidéolaryngoscope McGrath® - une première évaluation clinique]

Ben Shippey, BMBS MRCP FRCA, David Ray, MD FRCA and Dermot McKeown, MBChB FRCA

From the Department of Anesthesia, Critical Care and Pain Medicine, Royal Infirmary of Edinburgh, Edinburgh, Scotland.

Address correspondence to: Dr. Ben Shippey, Department of Anesthesia, Critical Care and Pain Medicine, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA, Scotland. Phone: +441312423224; E-mail: benshippey{at}mac.com

Purpose: To document tracheal intubation success rates and airway instrumentation times using the newly designed McGrath® videolaryngoscope.

Methods: We prospectively recorded factors associated with difficult tracheal intubation, factors causing actual difficulty in tracheal intubation, as well as complications arising from use of the new McGrath® videolaryngoscope in a series of adult patients with normal preoperative airway examinations. All patients were undergoing scheduled or elective surgery. In the first 75 patients (phase I), experience with airway instrumentation was documented, while in the second 75 patients (phase II), the time required to obtain an optimal view of the larynx was recorded, as well as the time to complete tracheal intubation.

Results: Ninety-eight percent of all tracheal intubations were successful using the McGrath® videolaryngoscope. Cormack and Lehane grade I views were obtained in 143 patients (95%) and grade II views were achieved in six (4%). In phase II, the median time required to obtain an adequate view was 6.3 sec [interquartile range 4.7–8.7 (range 2–26.3)], and to complete tracheal intubation was 24.7 sec [18.5–34.4 (11.4–286)]. Fortynine (65%) of the tracheal intubations were completed within 30 sec, and 72 (96%) were completed within one minute. No complications were encountered in any patient.

Conclusions: The McGrath® videolaryngoscope is an effective aid to airway management in patients with normal airways, based upon intubation success rates and the ability to rapidly secure the airway. Its potential advantages of convenience and portability warrant further evaluation in comparison with other airway devices and in patients with difficult airways.




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
G. L. Savoldelli and E. Schiffer
Videolaryngoscopy for tracheal intubation: the guide channel or steering techniques for endotracheal tube placement?
Can J Anesth, January 1, 2008; 55(1): 59 - 60.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the Canadian Anesthesiologists' Society.