CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by McKay, W.
Right arrow Articles by Chin, G.
PubMed
Right arrow PubMed Citation
Right arrow Articles by McKay, W.
Right arrow Articles by Chin, G.
Canadian Journal of Anesthesia 55:450019 (2008)
© Canadian Anesthesiologists' Society, 2008


meeting-abstract

450019 - ACCELEROMETER-BASED MUSCLE-STIMULATION NEUROMUSCULAR BLOCKADE MONITORING: A PILOT STUDY

William McKay, MD, Ayoub Dangor, MD and Garrett Chin, BSc

Anesthesia, University of Saskatchewan, Saskatoon, SK, Canada

Abstract

Introduction: Recent findings suggest that stimulation of intramuscular nerves by surface stimulating electrodes over muscle bellies instead of directly over peripheral nerves could be used to monitor pharmacologic neuromuscular blockade.[1,2,3] Accelerometer-based assessment of the strength of response to peripheral nerve stimulation has been shown to be clinically useful. This experiment compares stimulation over biceps muscle bellies using a commercially available accelerometer-based nerve stimulator (ABNS) with traditional ulnar nerve stimulation at the wrist sensed by a force transducer.

Methods: With Research Ethics Board approval, 10 consenting adults booked for elective surgery under general anesthetic that normally requires paralysis were recruited. The commonest and most-studied stimulation pattern for traditional nerve stimulators, the "train-of-four" (TOF, a set of 4 0.2ms supra-maximal stimuli at 2Hz, followed by a ten second pause) stimulating the ulnar nerve at the wrist was used. A force transducer was attached to the thumb of the splinted hand. The thumb was abducted to a resting force of 250 +/– 50g (2.45N). This standard method of TOF with force transducer (S-TOF) was applied to the left upper limb abducted on an arm board. The ABNS was attached with the accelerometer placed at the midpoint of the left biceps, midway between stimulating electrodes 10 cm apart on the long axis of the muscle. The ratio of the 4th to 1st TOF ratio S-TOF was compared to the TOF ratio generated by a TOF-Watch® ABNS (A-TOF).

Results: Ten subjects were recruited, 5 male and 5 female; age 43 ± 15years; 169 ± 7cm tall; and weighing 83 ± 18kg. Regression of A-TOF on simultaneous S-TOF: R2 = 0.54; P < 0.001. Bland and Altman analysis: mean difference = 0.48 percent; 1.96SD = 53.3 percent; three points lie beyond the 1.96SD limits (see graph).

Discussion: The TOF-Watch® used with muscle-belly stimulation and sensing is not a reliable neuromuscular monitor. However, we observed that there was often visible twitching when the TOF-Watch TOF registered zero. This may be because the TOF-Watch accelerometer is one-dimensional. We will next investigate whether a 3-dimensional accelerometer can give more-useful information.


Figure 1

References:

[1] Can J Anesth 2003; 50:342–347[Abstract/Free Full Text]

[2] Can J Anesth 2003 50:864–865.[Free Full Text]

[3] J Clin Monit 1999; 15:341–345